Agreement of the performance of equine electrocardiogram recording devices for ECG complexity analysis
Vadim Alexeenko1, Dhruvpal Singh Anchan1, Fe Ter Woort2
1University of Surrey, Guildford, UK.
Background:
Non-linear equine electrocardiography (ECG) analysis is an actively developing study area which has the potential to lead to novel, artificial intelligence-based diagnostic tools in equine cardiology. As more ECG recording devices are becoming available, there is a need to ensure results are interchangeable regardless of the equipment used to record the equine ECG.
Objectives:
To evaluate the agreement of ECG complexity values obtained using the Televet™ and Equimetre™ systems.
Study Design:
Cross-sectional clinical.
Methods:
ECGs were recorded using two devices simultaneously from 37 healthy Thoroughbred horses during routine training. An automated algorithm extracting the ECG segments of acceptable quality extracted 60-second strips with a stable heart rate in the range 30-100 beats per minute. Threshold-crossing, beat detection, and feature detection coarse-graining algorithms were used to annotate the ECG for complexity analysis. Complexity values were corrected to the heart rate using data from 37 horses, and inter-device agreement was evaluated using Bland-Altman plots and Student's t-test using ECG data from 28 horses that provided sufficient data from both devices.
Results:
The results of complexity analysis obtained with beat detection coarse-graining were independent of the device used at all heart rates. The results obtained with feature detection for heart rates below 75 beats per minute (bpm) and with threshold crossing for heart rates above 75 bpm were significantly different.
Main Limitations:
The study relied on convenience sampling, and data analysis was constrained by the availability of ECG data in the heart rate range of interest.
Conclusions:
The accurate comparison of ECG complexity analysis results requires consideration of differences between recording devices, heart rates and ECG coarse-graining techniques.
More Related Videos
Related Concept Videos
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and...
Instrumentation Amplifier
To overcome this challenge, an ECG machine utilizes an instrumentation amplifier. This specialized amplifier is...
Electrocardiogram Fundamentals
An electrocardiogram (ECG) is a diagnostic tool for identifying cardiac conditions such as arrhythmias, conduction abnormalities, and myocardial ischemia.
Definition
An electrocardiogram (ECG) visualizes the heart's electrical activity by tracing the electrical movement associated with each heartbeat on a graph or monitor. As the heart beats, an electrical wave passes through it, correlating with the cardiac cycle events.
Parts of an ECG
An ECG utilizes electrodes on the skin...
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...
ECG Interpretation of Rhythms
Components of the Electrocardiogram
The primary components of a normal ECG waveform in Normal sinus rhythm(NSR) include the P wave, PR interval, QRS complex, ST segment, T wave, and occasionally a U wave.
ECG waveforms are divided by vertical and horizontal lines at standard intervals.
The horizontal axis measures time and rate, and the vertical axis measures amplitude or voltage....
Dysrhythmias V: Evaluating Dysrhythmias