Related Experiment Video
Updated: Jan 10, 2026

3D Cine Magnetic Resonance Imaging of Respiratory Motion in Mechanically Ventilated Mice and Rats
Published on: September 19, 2025
Mechanical power in mechanical ventilation and its association with ventilator-induced lung injury: A systematic
Tomasz Urbankowski1, Raman Pasledni1, Marek Darowski1
1Department of Modeling and Supporting of Internal Organs Functions, Nalecz Institute of Biocybernetics and Biomedical Engineering, Polish Academy of Sciences, ul. Ks. Trojdena 4, 02-109, Warsaw, Poland.
Background:
Mechanical power (MP) quantifies the total energy delivered from the ventilator to the respiratory system per unit time, integrating tidal volume, airway pressures, respiratory rate, and flow. MP has been proposed as a surrogate marker of ventilator-induced lung injury (VILI), but the consistency and generalizability of this association across patient populations remain uncertain.
Objectives:
To provide the most comprehensive systematic evaluation to date of the relationship between MP and VILI-related outcomes in adult patients receiving invasive mechanical ventilation.
Methods:
We conducted a systematic review following PRISMA guidelines. Four databases (PubMed, Embase, Scopus, Web of Science) were searched for original studies reporting MP and clinical outcomes related to VILI. Risk of bias was assessed using RoB 2.0 and ROBINS-I tools. Certainty of evidence was rated using the GRADE approach.
Results:
Forty-six studies including 314,823 patients were analyzed. Forty (87 %) demonstrated a statistically significant association between higher MP and adverse outcomes (mortality, prolonged ventilation, or ICU stay). Threshold effects were identified in 23 studies, most consistently between 14 and 18 J/min. Normalized MP (e.g., per predicted body weight or well-aerated lung volume) improved prognostic performance in selected cohorts. Despite heterogeneity and mostly observational designs, the overall signal was robust across diverse populations and clinical contexts.
Conclusions:
This review establishes mechanical power as a consistent and clinically relevant predictor of adverse outcomes in mechanically ventilated adults. By synthesizing >300,000 patients, it provides the most reliable evidence base to date, identifies reproducible thresholds, and highlights the importance of normalization strategies. These findings suggest that MP could complement tidal volume and driving pressure in lung-protective ventilation and define priorities for future prospective trials.
Related Concept Videos
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Mechanical Ventilation I: Indication and Settings
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...
Ventilatory Modes
There are three ventilatory modes: full support, partial support, and spontaneous. These are described below.
Full Support Modes
Full support modes include controlled mechanical ventilation, continuous mandatory...
Pulmonary Ventilation: Inhalation
Boyle's law becomes particularly pertinent when examining respiratory...

