Related Experiment Video
Updated: Jan 10, 2026

Author Spotlight: Simulation and Analysis of the Temperature Rise of Ring Main Unit Equipment
Published on: July 5, 2024
Estimating the insulation health index of XLPE cables using machine learning
Adel Ansari1, Sorin Yousef Nia2, Alireza Afshari3
1Tarbiat Modares University, Tehran, Iran. adelansari@modares.ac.ir.
Abstract:
This paper focuses on the development of a robust machine learning-based health index model specifically for medium voltage (MV) underground cables insulated with cross-linked polyethylene (XLPE). Maintaining the health and reliability of MV cables is crucial for effective power distribution, as failures can lead to financial losses and outages. Traditionally, maintenance has been reactive, addressing issues only after failures occur, which is costly and results in unnecessary service interruptions. To address this issue, this study introduces a predictive health index model developed using machine learning (ML) techniques. The model aims to shift maintenance strategies from reactive to proactive by identifying cables at risk of failure before they become critical. The dataset used to train the model include various parameters such as environmental factors (moisture, temperature), cable characteristics (age, insulation integrity), and historical performance data (load, partial discharges). By analyzing this dataset, ML algorithms-including Support Vector Machine (SVM), K-Nearest Neighbors (K-NN), Artificial Neural Networks (ANN), and Naïve Bayes-were used to classify cables into distinct health categories, ranging from healthy to at-risk. The results indicate that ANN outperforms conventional methods, achieving 94.5% accuracy-a 12% improvement. Compared to reactive maintenance, this model improves fault prediction by 30% and reduces maintenance costs by 25%.
Related Concept Videos
Insulation Coordination
Cable Subjected to Its Own Weight
A generalized loading function is employed to analyze a cable subjected to its own weight. This function considers the force acting along the cable's arc length rather than its projected length, providing a more accurate...
Cable Subjected to a Distributed Load
Energy Stored In A Coaxial Cable
In the simplest form, a coaxial cable can be represented by two long hollow concentric cylinders in which the current flows in opposite directions. The magnetic field inside and outside the coaxial cable is determined by using Ampère's law. The magnetic field inside...
Cable: Problem Solving
Calculation of Self-inductance
Since the effect of the induced electric field and the back EMF generated depends on the rate of change of current and the self-inductance, the inductance...