Related Experiment Video
Updated: Jan 10, 2026

Author Spotlight: Advancements in Refractive Surgical Correction for Presbyopia and Exploring Postoperative Visual Acuity
Published on: September 20, 2024
Visual and functional outcomes of a new diffractive trifocal intraocular lens with smooth micro phase technology in
Javier Mendicute1,2, Gorka Lauzirika1,3, Maider Arratibel-Alkorta1
1Miranza Begitek, Donostia 20012, San Sebastián, Spain.
Aim:
To assess the refractive and functional outcomes of a novel trifocal intraocular lens (IOL) with smooth micro phase technology.
Methods:
This prospective, single-arm, single-center, observational study included patients who underwent cataract surgery with the implantation of the AT ELANA 841P (Carl Zeiss Meditec, Berlin, Germany) IOL. Visual acuity (VA) at distance, intermediate, and near were evaluated 1- and 3-month postop as well as refractive outcomes. Monocular and binocular defocus curve, binocular contrast sensitivity (M&S® Technologies) and patient satisfaction with the Catquest-9SF questionnaire were measured at 3-month postop.
Results:
In total, 46 eyes (23 patients) were bilaterally implanted with the IOL. Mean patient age was 59.86±5.55y. At 1-month postop, monocular corrected VA for distance, intermediate, and near were -0.15±0.09, 0.11±0.10, and 0.15±0.12 logMAR, respectively. These outcomes remained stable at the 3-month follow-up (P>0.05). Spherical equivalent (SE) at 1- and 3-month postop remained stable (P>0.05). Following surgery, 91% of the eyes at 1mo and 95% of the eyes at 3mo were within ±0.5 D of SE. Monocular defocus curve showed that the lens can be categorized as a steep transition IOL. The contrast sensitivity function revealed high values at low spatial frequencies and decreased values at high spatial frequencies. The results of the Catquest-9SF questionnaire showed that all patients were fairly or very satisfied with their vision after surgery.
Conclusion:
The AT ELANA 841P IOL offers excellent visual outcomes across distance, intermediate, and near ranges, along with satisfactory contrast sensitivity. Additionally, the lens is associated with high patient satisfaction and minimal visual difficulties during daily activities.
More Related Videos
05:14Comparison of Agreement and Accuracy using Binocular Wavefront Optometer with Autorefractor and Phoropter
Published on: September 16, 2025
04:59Author Spotlight: Enhancing Visual Outcomes in Cataract Surgery: A Novel Technique to Prevent Posterior Capsular Opacification Through IOL Rotation
Published on: July 7, 2023
Related Concept Videos
Angle Closure Glaucoma: Treatment
Open Angle Glaucoma: Treatment
Drugs such as carbonic anhydrase inhibitors, α2- and...
Focusing of Light in the Eye
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...