Related Experiment Video
Updated: Jan 10, 2026

Preparation, Purification, and Characterization of Lanthanide Complexes for Use as Contrast Agents for Magnetic Resonance Imaging
Published on: July 21, 2011
Transition metal doping for improving the fluorescence response of paralytic shellfish poisoning toxins upon
1Sea and Marine Resources Department (DMRM), The Portuguese Sea and Atmosphere Institute, I.P. (IPMA, IP), Algés, Portugal.
Abstract:
Paralytic shellfish toxins can be quantified in bivalves by the AOAC-2005 method. This method is sensitive for several toxins, but other toxins suffer from strong matrix effects or fluorescence partitioning by multiple oxidation products, reducing their sensitivity. Metals were assessed as candidate catalysts to improve the oxidation reactions, instead of the oyster matrix modifier prescribed in this method. The N1-H sub-group of toxins exhibited increased fluorescence upon doping with iron sulphate. The increase was inversely proportional to the fluorescence reduction caused by matrix suppression. Iron acted as a catalyst, lowering the activation energy of the reaction, which otherwise required heating to achieve a similar boost in the fluorescence yield. The fluorescence due to the N1-hydroxyl sub-group of toxins GTX1 + 4 and GTX6 increased with zinc but decreased with iron. When doping with a metal solution fraction-2 of the carboxylic acid partitioning, both metals reduced the fluorescence, while the eluent (NaCL 0.05 M) enhanced it. As metals are retained by COOH cartridges, sulphonic acid leachables might contribute to this reduction. The reduction observed for GTX1 + 4 was primarily due to the decrease in the proportion of the secondary peak over the primary oxidation peak, which can be reversed by doping with an oyster matrix. Nickel chloride was able to replace the oyster modifier effectively in all five bivalve matrices tested, while zinc chloride was not similarly effective. For dcNEO spiked in several bivalve matrices, adding an oyster modifier derived from Magallana gigas caused a 16-19% reduction in fluorescence. Doping with several metals could not achieve the same fluorescence as doping with 0.1 mM acetic acid. For NEO, with one particular oyster extract, the yield could be higher than using NiCl2. Depending on the specific oyster extract, the use of the matrix modifier required in the method might not be adequate.
More Related Videos
06:25Post Column Derivatization Using Reaction Flow High Performance Liquid Chromatography Columns
Published on: April 26, 2016
09:34Improved Polymerase Chain Reaction-restriction Fragment Length Polymorphism Genotyping of Toxic Pufferfish by Liquid Chromatography/Mass Spectrometry
Published on: September 20, 2016
Related Concept Videos
Photoluminescence: Applications
Extraction: Advanced Methods
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...
Masking and Demasking Agents
There are many masking agents, such as cyanide, fluoride, triethanolamine, thiourea, and 2,3-bis(sulfanyl)propan-1-ol (formerly 2,3-dimercapto-1-propanol), with the masking agent chosen based on...