Related Experiment Video
Updated: Jan 10, 2026

Design and Optimization Strategies of a High-Performance Vented Box
Published on: June 9, 2023
Quantitative Assessment of CFD-Based Micro-Scale Renovation of Existing Building Component Envelopes
1School of Design and Art, Jiangxi University of Finance and Economics, Nanchang 330031, China.
Abstract:
With the acceleration of urbanization, environmental degradation is increasingly restricting the improvement of residents' quality of life, and promoting the transformation of old communities has become a key path for sustainable urban development. However, existing buildings generally face challenges, such as the deterioration of the performance of the envelope structure and the rising energy consumption of the air conditioning system, which pose a serious test for the realization of green renovation. Inspired by the application of bionics in the field of architecture, this study innovatively designed five types of bionic envelope structures for outdoor air conditioning units, namely scales, honeycombs, spider webs, leaves, and bird nests, based on the aerodynamic characteristics of biological prototypes. The ventilation performance of these structures was evaluated at three scales-namely, single building, townhouse, and community-under natural ventilation conditions, using a CFD simulation system. The study shows the following: (1) the spider web structure has the best comprehensive performance among all types of enclosures, which can significantly improve the uniformity of the flow field and effectively eliminate the low-speed stagnation area on the windward side; (2) the structure reorganizes the flow structure of the near-wall area through the cutting and diversion of the porous grid, reduces the wake range, and weakens the negative pressure intensity, making the pressure distribution around the building more balanced; (3) in the height range of 1.5-27 m, the spider web structure performs particularly well at the townhouse and community scales, with an average wind speed increase of 1.1-1.4%; and (4) the design takes into account both the safety of the enclosure and the comfort of the pedestrian area, achieving a synergistic optimization of function and performance. This study provides new ideas for the micro-renewal of buildings, based on bionic principles, and has theoretical and practical value for improving the wind environment quality of old communities and promoting low-carbon urban development.
More Related Videos
Related Concept Videos
Thermal Insulation in Masonry Walls
External insulation can be applied using an Exterior Insulation and Finish System (EIFS), which involves affixing panels of plastic foam to the wall and covering them with a polymeric stucco reinforced with glass fiber mesh....
Measurement of Air Content in Concrete
The pressure method,...
Design Example: Dimensioning of Concrete Masonry Construction
The site engineer has laid out a plan for the storeroom with external dimensions of twelve feet in length and...
Design Example: Sustainability in Concrete Building
There are multiple approaches to achieve sustainability in a commercial concrete building. For instance, construct a concrete parking area under the building, utilizing pervious concrete paver blocks in open areas to facilitate rainwater collection through an underground...
Conduction, Convection and Radiation: Problem Solving
In order to solve a problem related to heat transfer, first of all, the situation needs to be examined to determine the type of heat transfer involved. This could...
Design Example: Analyzing Capacity Contours for Flood Risk Assessment

