Encoding historical traffic scenarios is critical for autonomous driving trajectory prediction. However, existing methods face two fundamental challenges. First, neglecting future interactions leads to myopic predictions. Second, although query-centric paradigms capture multimodal interactions, their typically static query design may limit the adaptability of cross-temporal context fusion. To address these limitations, we propose Miformer, a trajectory prediction model that enhances historical-future spatial-temporal context interactions. First, we introduce a time query mechanism that transforms static agent interactions into dynamic temporal modeling by enabling cross-timestep information exchange between different agents and road geometry. Building upon this temporal foundation, we design a historical-future spatial-temporal interaction module (HF-STIM) that leverages iTransformer to model bidirectional dependencies between past and future contexts. To address the redundancy inherent in inverted embeddings, we further propose the minus-inverted Transformer (Mi-Transformer), which incorporates a dynamic residual learning mechanism to eliminate irrelevant dependencies while preserving critical bidirectional information flow. Finally, we employ a DETR-like decoder to generate diverse multimodal trajectory predictions. Experimental results demonstrate that Miformer achieves state-of-the-art performance on the INTERACTION dataset and exhibits competitive performance on the Argoverse dataset. These results highlight its effectiveness in real-world motion prediction. Our code is available at https://github.com/Morphlingxxx/Miformer-Trajectory-Prediction.
Related Concept Videos
Types Of Transformers
If the ratio of the number of turns in the secondary winding to that of the primary winding is greater than one, then the transformer is said to be a step-up transformer. In a step-up transformer, the voltage at the secondary winding is greater than the voltage applied at the primary winding.
However, if this ratio is less than one, the transformer is said to be a step-down...
Energy Losses in Transformers
There are four main reasons for energy losses in transformers.
The first cause can be the high resistance of the...
Reducing Line Loss
With a step-up transformer at the source, the voltage is increased, thereby reducing the current in the transmission lines since power loss in...
Transformers with Off-Nominal Turns Ratios
Per-Unit Sequence Models
Zero-sequence currents, which are identical in magnitude and phase, generate a neutral current, resulting in voltage drops across the neutral impedance and the low-voltage winding. If the...
Simplified Synchronous Machine Model
In this model, each generator is connected to a...