Related Experiment Video
Updated: Jan 10, 2026

Quantitative Analysis by Thermogravimetry-Mass Spectrum Analysis for Reactions with Evolved Gases
Published on: October 29, 2018
Quantification of Volatile Compounds in Mixtures Using a Single Thermally Modulated MOS Gas Sensor with PCA-ANN Data
1Faculty of Food Science and Nutrition, Poznań University of Life Sciences, 60-624 Poznań, Poland.
None:
Recent research efforts have focused on improving the performance of metal-oxide semiconductor (MOS) gas sensors through their thermal modulation using integrated heaters. This approach allows us to enhance the selectivity of measurements; however, the main challenge with this amelioration lies in interpreting the sensor response, which takes the form of complex patterns that require the application of advanced signal processing techniques. This study introduces a methodology for the quantitative determination of volatile compounds (ethanol and methanol at various concentrations ranging from 31 to 2000 ppm for each of these compounds) in mixtures using a single thermally modulated MOS gas sensor. The recorded responses of the detector were interpreted by combining two signal processing techniques: principal component analysis (PCA) for feature extraction, and artificial neural networks (ANNs) for predicting the levels of the tested volatile components. The proposed methodology demonstrated satisfactory performance achieving R2 values at the level of 0.999 across all datasets (learning, test, validation) and low error metrics (RMSE = 11.6-14.4 ppm), thereby confirming the robustness and accuracy of the approach and its applicability in a wide range of fields where rapid, cost-effective, and precise detection of ethanol and methanol is essential.
Related Concept Videos
Volatilization
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...