Assessment of carotid atherosclerotic plaque vulnerability with multi-radiotracer PET/CT: a scoping review
Thomas R Readford1,2, Peter L Kench1, Martin Ugander1,3,4
1Faculty of Medicine and Health, The University of Sydney, Sydney, Australia.
Objectives:
Atherosclerotic carotid artery disease (CarAD) is a significant contributor to the global burden of cerebrovascular diseases. Several positron emission tomography computed tomography (PET/CT) radiotracers showed promising results in identifying and assessing vulnerable carotid atherosclerotic plaque. This review aims to assess the current evidence surrounding the use and potential of multiple PET radiotracers in identifying vulnerable carotid atherosclerotic plaque.
Materials And Methods:
A scoping review of the literature was conducted for original peer-reviewed articles of PET studies published between 2010 and 2024 that used 18F-fluorodeoxyglucose (18F-FDG), 18F-sodium fluoride (18F-NaF), 18F-fluoromisonidazole (18F-FMISO), 68Ga-DOTATATE, 68Ga-Pentixafor, and 11C-Acetate for the evaluation of vulnerable carotid atherosclerotic plaque. The Covidence platform facilitated the screening of articles and data extraction.
Results:
37 studies matched the inclusion criteria. Seven (19%) included serial dual-tracer PET/CT with 18F-FDG/18F-NaF, 18F-FDG/18F-FMISO, 18F-FDG/68Ga-DOTATATE, and 18F-FDG/68Ga-Pentixafor. The remaining studies used PET/CT 18F-FDG (N = 26, 70%), 18F-NaF (N = 2, 5%), 11C-Acetate (N = 1, 3%) and 68Ga-DOTATATE (N = 1, 3%). Substantial variation in PET/CT acquisition parameters such as uptake time (min) [18F-FDG: 50-180, 18F-NaF: 60-180, and 68Ga-DOTATATE: 60-120], radiotracer dose (MBq) [18F-FDG: 185-555, 18F-NaF: 125-370] and analysis methods [target-to-background ratio and/or standardised uptake values] were observed with no clear consensus on what constitutes a standard approach for carotid plaque evaluation using PET/CT.
Conclusion:
The use of multiple PET radiotracers may provide novel diagnostic insights into the diagnosis of CarAD and improve the identification of vulnerable carotid atherosclerotic plaque. However, protocol heterogeneity affects reproducibility, necessitating standardised imaging parameters and histological validation to enable future clinical use of PET for CarAD assessment.
Key Points:
Question Conventional atherosclerotic plaque assessments, focusing on vessel occlusion, lack predictive power for vulnerable carotid atherosclerotic plaque. Can multi-radiotracer PET/CT, targeting plaque metabolic processes, address this? Findings Multi-radiotracer PET/CT demonstrates promising potential in detecting vulnerable carotid atherosclerotic plaque, but variability in data acquisition and analysis methods persists. Clinical relevance This review shows that multi-radiotracer PET/CT may provide novel diagnostic insights for detecting vulnerable carotid atherosclerotic plaque, potentially enhancing risk assessment and identifying patients at higher risk of cerebrovascular events.
More Related Videos
11:09High-Resolution Cardiac Positron Emission Tomography/Computed Tomography for Small Animals
Published on: December 16, 2022
09:36A Magnetic Resonance Imaging-based Computational Protocol for Analysis of Plaque Morphology and Hemodynamics in Patients with Carotid Artery Stenosis
Published on: August 12, 2025
Related Concept Videos
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies for Cardiovascular System V: CT
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
![Quantification of Atherosclerotic Plaque Activity and Vascular Inflammation using [18-F] Fluorodeoxyglucose Positron Emission Tomography/Computed Tomography FDG-PET/CT](/_next/image?url=https%3A%2F%2Fcloudfront.jove.com%2FCDNSource%2Fteasers%2F3777.jpg&w=3840&q=50)