Related Experiment Video
Updated: Jan 10, 2026

A Whole Body Dosimetry Protocol for Peptide-Receptor Radionuclide Therapy PRRT: 2D Planar Image and Hybrid 2D+3D SPECT/CT Image Methods
Published on: April 24, 2020
Comparison of Approximate Mathematical Formulas for Optimal Organ Absorbed Dose Estimation in CT Examination of the
Masato Takanashi1, Isao Kuroda2, Shinji Sugahara1
1Department of Radiology and Radiation Oncology, Tokyo Medical University Ibaraki Medical Center, Inashiki-gun, JPN.
Abstract:
Computed tomography (CT) examinations account for a large proportion of all medical exposures. Therefore, various studies on radiation exposure have been conducted. The automatic exposure control system is commonly used in CT examinations, and its characteristics vary from equipment to equipment, which may affect the approximate formulas and coefficients of determination (R2). The purpose of this study is to compare the organ-specific absorbed dose approximate formulas for different CT equipment with the literature and to verify the optimal approximate formula. The subjects were 224 consecutive adult male patients who underwent abdominopelvic CT examinations in 2020, using an Aquilion ONE/PRISM Edition CT equipment (Canon Medical Systems, Inc., Tochigi, Japan). The vertical axis was the absorbed dose to the organs estimated by Monte Carlo simulation using Radimetrics version 3.3 (Bayer Medical Care Inc., Whippany, NJ), a dose management software (DMS). The target organs were the liver, kidney, and colon. The horizontal axis was the dose-length product (DLP) and the size-specific dose estimate (SSDE) calculated by Radimetrics. The approximate formulas analyzed were linear, power, and logarithmic. All organ-absorbed doses had the highest R2 in the logarithmic approximation. By calculating the approximate formula from specimens of one's own facility, one can estimate the absorbed dose for each organ with a high degree of accuracy without using DMS.
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Abdominal Regions and Quadrants
The simpler quadrants approach, which is more commonly used in medicine, subdivides the cavity with one horizontal and one vertical line that intersects at the patient's umbilicus (navel). The four...
Radiological Investigation I: X-ray and CT
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...