Related Experiment Video
Updated: Jan 10, 2026

A Protocol of Manual Tests to Measure Sensation and Pain in Humans
Published on: December 19, 2016
Reliability of an algometry device for pain pressure threshold evaluation in athletes: A pilot study
Shahab Alizadeh1, Emad Sharifi2, Mohammad Hossein Alizadeh3
1Human Performance Lab, Faculty of Kinesiology, University of Calgary, Calgary, Alberta, Canada.
Abstract:
The pain pressure threshold is a metric used in both rehabilitation and diagnostic settings for various applications. Typically, this threshold is determined using a handheld dynamometer or an analog/digital algometer, which measures sensitivity to the onset of pain. However, human administration of pressure is prone to errors due to variations in the rate of force application, angle of application, and human responsiveness. In this study, we aimed to develop a prototype device that automates pressure applications. This device can apply pressure at different rates and angles, allowing participants to cease pressure application autonomously. The device was tested on the rectus femoris of 41 participants (30 males and 11 females), and the rate of force application was set to 0.05 m/s at a 90-degree angle. The device's reliability was assessed using intra-class correlation (ICC), and the results demonstrated high reliability (ICC = 0.91) for both males and females with a standard error of measurement of 4.34. Statistical analysis revealed that males exhibited a significantly higher pain pressure threshold than females. This study confirms the reliability of the prototype device in measuring pain pressure threshold with minimal examiner intervention. Additionally, the higher pain pressure threshold of males, suggests lower sensitivity to pressure pain compared to females.
More Related Videos
07:28Psychophysically-anchored, Robust Thresholding in Studying Pain-related Lateralization of Oscillatory Prestimulus Activity
Published on: January 21, 2017
09:03Optimizing Photoneuromodulation Techniques to Evaluate the Role of Green Light-Emitting Diodes in Pain Management
Published on: March 28, 2025
Related Concept Videos
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...