Recognition method for microgrid switching misoperations based on multi-source heterogeneous data fusion
Hongzhao Yang1,2,3, Zhan Zhang4,5, Shijie Zhang6,7
1School of Software, Changsha Social Work College, Changsha, 410004, China. Yhz21star@qq.com.
None:
To enhance the safety of microgrid switching and the identification of misoperations, we propose Time-Synchronized Misoperation Recognition (TS-MR), a method tailored to switching operations. The approach performs rule-based pre-screening grounded in operating procedures and anti-misoperation interlocking, achieves millisecond-level time synchronization of multi-source heterogeneous data via a two-stage scheme that combines variational Bayesian inference with a UKF, and employs a fusion of a Transformer, a TCN, and a GNN for cross-modal representation with interpretable discrimination. Laboratory records constitute the training, validation, and test sets; HIL data are used solely for independent cross-validation; and public datasets are used only for cross-domain robustness calibration, and none contributes to training, validation, or threshold tuning. Under a unified evaluation protocol, TS-MR attains 94.69% accuracy and an AUC of 0.977 in typical switching scenarios; end-to-end latency is about 80 ms; the core forward-pass latency is about 42 ms; the [Formula: see text] per-inference latency is 55 ms; and computational complexity is about 3.4 GFLOPs. Compared with CNN-BiLSTM, ConvLSTM, and GAT under identical preprocessing, time synchronization, and fixed random seeds, TS-MR improves accuracy by 0.9 to 3.7% points and AUC by 0.024 to 0.057. These results indicate that TS-MR provides high-confidence misoperation recognition and interpretable assessment for microgrid switching while satisfying engineering-grade real-time constraints.
Related Concept Videos
Reclosers and Fuses
A comprehensive protection scheme for radial distribution...
Multimachine Stability
In analyzing the system, the nodal equations represent the relationship between bus voltages, machine voltages, and machine currents. The nodal equation is given by:
Power System Three-Phase Short Circuits
Line Protection with Impedance Relays
Under normal conditions, low load currents keep the measured...
Fast Decoupled and DC Powerflow
Bus Impedance Matrix
In the first circuit, all machine voltage sources are short-circuited, leaving only the prefault voltage source at the fault location. The positive-sequence bus impedance matrix can be determined by solving the nodal equations,...