Visualizing Cardiac Motion Using Subcutaneously Measured Electrocardiography and Three-Axis Acceleration: Day-to-Day
Abstract:
Continuous monitoring of cardiac motion offers valuable insights into heart failure (HF) progression and management. This study explores a method to visualize heart motion trajectories from a novel subcutaneous sensor by integrating electrocardiogram (ECG) data with data from a three-axis accelerometer. The area of the plane covered by those trajectories may enable assessing changing cardiac function quantitatively. During systole the trajectories clearly showed multi-axial mechanical motion of the contracting chest following the cardiac ejection of blood from the left ventricle into the systemic circulation. Consistent daily trajectory patterns were observed in a stable individual on eight different days as their systolic area covered was comparable in size (0.0140mm2 ± 0.054mm2) and orientation. Four Patients that experienced five congestive heart failure events (CHF) showed a reduced systolic plane prior to clinical deterioration as the systolic trajectory area covered was significantly reduced compared to baseline (0.0061mm2 ± 0.0044mm2 at the event versus 0.0158mm2 ± 0.0096mm2 at baseline, p<0.05). Previous research reported qualitatively similar trajectories in healthy volunteers using non-invasive sensors. Additionally, while devices such as other subcutaneous monitoring implants have been evaluated for monitoring ECG and impedance changes in patients with HF, the potential of subcutaneous three-dimensional acceleration measurements remains unexplored. Our findings suggest that this integrated approach could enhance remote monitoring, early detection of decompensation, and personalized treatment strategies for HF patients.Clinical Relevance-This study reports a more intuitive means to display ECG and three-axis acceleration data from a novel subcutaneous sensor. The raw data is converted to cardiac displacement trajectories. The results show that the cardiac motion range reduced in heart failure patients that experienced congestion and heart failure related events.
More Related Videos
11:13Quantification of Mouse Heart Left Ventricular Function, Myocardial Strain, and Hemodynamic Forces by Cardiovascular Magnetic Resonance Imaging
Published on: May 24, 2021
12:45Benefits of Cardiac Resynchronization Therapy in an Asynchronous Heart Failure Model Induced by Left Bundle Branch Ablation and Rapid Pacing
Published on: December 11, 2017
Related Concept Videos
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and...
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion,...
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...
Holter Monitor: 24-Hour Monitoring