Exploring the Effect of LED-to-Photodetector Spacing on Subcutaneous Photoplethysmography for Continuous Blood
None:
Photoplethysmography (PPG) is widely used to measure heart rate, blood oxygenation, and more recently, blood pressure. Implanted PPG systems offer the possibility to measure similar real-time measures of cardiovascular health, however, the detection method may vary due to a lack of capillary vessels for PPG sensors to observe in muscle tissue. To improve volumetric blood detection in large muscles, without relying on the capillary density of skin, a flexible PPG sensor was developed. The sensor included multiple spacing of illuminating infrared (IR) light emitting diodes (LEDs) and a single IR photodetector. This arrangement was expected to enable detection of blood volume changes at variable distances from the sensor face, potentially at much longer depths then feasible with skin-mounted PPG devices. IR bench phantoms simulating a large blood vessel embedded in IR absorbing, tissue-mimicking rubber were developed and used to determine the sensor performance in vitro. A preliminary in vivo test used an adult rabbit to provide additional performance validation. Test results reveal an observed trend of increased SNR for deeper vessel depths for the farthest LED to detector spacing which is aligned with our initial prediction. However, ANOVA and post-hoc tests reveal that these trends did not reach statistical significance. The in vivo test showed a relationship consistent with relevant literature. Future experiments are required to improve the phantom's representation of the biological setting and to confirm a reduced SNR variation for the farthest spacing.Clinical Relevance-Development of a subcutaneous, continuous blood pressure sensor may provide benefits towards monitoring autonomic dysreflexia and hypertension for people affected by spinal cord injury.
More Related Videos
07:20A Novel Approach to Overcome Movement Artifact When Using a Laser Speckle Contrast Imaging System for Alternating Speeds of Blood Microcirculation
Published on: August 30, 2017
04:44Author Spotlight: Enhancing Vascular Function and Physical Capacity in Cardiovascular Disease Through Novel Interventions and NIRS Technology
Published on: March 22, 2024
Related Concept Videos
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Pre-Procedural Guidelines for Assessing Blood Pressure
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Measurement of Blood Pressure
Assessment of blood pressure in brachial artery(two-step method)