Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Sensitivity, Specificity, and Predicted Value01:13

Sensitivity, Specificity, and Predicted Value

1.2K
In healthcare diagnostics, laboratory tests play a crucial role in identifying and diagnosing a wide range of medical conditions. However, interpreting test results is not always straightforward. An abnormal test result does not always confirm the presence of a disease, just as a normal result does not guarantee its absence. To assess the reliability of these diagnostic tools, healthcare practitioners rely on two key statistical indicators: sensitivity and specificity.
Sensitivity is the...
1.2K
Receiver Operating Characteristic Plot01:15

Receiver Operating Characteristic Plot

464
A ROC (Receiver Operating Characteristic) plot is a graphical tool used to assess the performance of a binary classification model by illustrating the trade-off between sensitivity (true positive rate) and specificity (false positive rate). By plotting sensitivity against 1 - specificity across various threshold settings, the ROC curve shows how well the model distinguishes between classes, with a curve closer to the top-left corner indicating a more accurate model. The area under the ROC curve...
464

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Real-World Performance of COVID-19 Antigen Tests: Predictive Modeling and Laboratory-Based Validation.

JMIRx med·2025
Same author

NS1-Specific Antibody Response Facilitates the Identification of Children With Dengue and Zika in Hyperendemic Areas.

The Pediatric infectious disease journal·2023
Same author

Development and Validation of a Rapid Lateral Flow E1/E2-Antigen Test and ELISA in Patients Infected with Emerging Asian Strain of Chikungunya Virus in the Americas.

Viruses·2020
Same author

Serotype-specific detection of dengue viruses in a nonstructural protein 1-based enzyme-linked immunosorbent assay validated with a multi-national cohort.

PLoS neglected tropical diseases·2020
Same author

Multivariate time-series analysis of biomarkers from a dengue cohort offers new approaches for diagnosis and prognosis.

PLoS neglected tropical diseases·2020
Same author

Field-deployable viral diagnostics using CRISPR-Cas13.

Science (New York, N.Y.)·2018
Same journal

Readability of AI-Generated Patient Information on Glucagon-Like Peptide-1 Receptor Agonists.

JMIR bioinformatics and biotechnology·2026
Same journal

Random Survival Forest Versus Elastic-Net Regularized Cox Regression for Survival Prediction in Acute Myeloid Leukemia at Distinct Treatment Time Points: Model Performance Comparison Study.

JMIR bioinformatics and biotechnology·2026
Same journal

Temporal Reproducibility of a Genetic Algorithm-Derived Health Risk Score: Standardized Out-of-Fold Validation Framework (2021-2023).

JMIR bioinformatics and biotechnology·2026
Same journal

The AudioGene Translational Dashboard for Diagnosing Autosomal Dominant Nonsyndromic Hearing Loss: Phenotypic Data Visualization and Analysis Study.

JMIR bioinformatics and biotechnology·2026
Same journal

A Strategic Partnership to Advance AI Applications in Genomics and Bioinformatics for Health Innovation.

JMIR bioinformatics and biotechnology·2026
Same journal

Prevalence and Associated Risk Factors of Bovine Fasciolosis in Bahir Dar, Ethiopia: Cross-Sectional Study.

JMIR bioinformatics and biotechnology·2026
See all related articles

Related Experiment Video

Updated: Jan 9, 2026

Developing a Salivary Antibody Multiplex Immunoassay to Measure Human Exposure to Environmental Pathogens
09:08

Developing a Salivary Antibody Multiplex Immunoassay to Measure Human Exposure to Environmental Pathogens

Published on: September 12, 2016

9.1K

Estimating Antigen Test Sensitivity via Target Distribution Balancing: Development and Validation Study.

Miguel Bosch1,2, Adriana Moreno2, Raul Colmenares2

  • 1IDX20 Inc, 166 Clinton Road, Brookline, MA, United States, 1 6177347745.

JMIR Bioinformatics and Biotechnology
|December 4, 2025
PubMed
Summary
This summary is machine-generated.

This study introduces a statistical method to standardize the sensitivity of lateral-flow antigen tests (ATs) by adjusting for viral load variations. This approach ensures fairer, more accurate comparisons of diagnostic test performance across different studies and suppliers.

Keywords:
COVID-19PPAantigen testpositive percent agreementreal-world datasensitivity estimation

More Related Videos

Application of Biochip Microfluidic Technology to Detect Serum Allergen-specific Immunoglobulin E sIgE
07:10

Application of Biochip Microfluidic Technology to Detect Serum Allergen-specific Immunoglobulin E sIgE

Published on: April 21, 2019

16.9K
Development and Validation of an Ultrasensitive Single Molecule Array Digital Enzyme-linked Immunosorbent Assay for Human Interferon-α
08:26

Development and Validation of an Ultrasensitive Single Molecule Array Digital Enzyme-linked Immunosorbent Assay for Human Interferon-α

Published on: June 14, 2018

12.5K

Related Experiment Videos

Last Updated: Jan 9, 2026

Developing a Salivary Antibody Multiplex Immunoassay to Measure Human Exposure to Environmental Pathogens
09:08

Developing a Salivary Antibody Multiplex Immunoassay to Measure Human Exposure to Environmental Pathogens

Published on: September 12, 2016

9.1K
Application of Biochip Microfluidic Technology to Detect Serum Allergen-specific Immunoglobulin E sIgE
07:10

Application of Biochip Microfluidic Technology to Detect Serum Allergen-specific Immunoglobulin E sIgE

Published on: April 21, 2019

16.9K
Development and Validation of an Ultrasensitive Single Molecule Array Digital Enzyme-linked Immunosorbent Assay for Human Interferon-α
08:26

Development and Validation of an Ultrasensitive Single Molecule Array Digital Enzyme-linked Immunosorbent Assay for Human Interferon-α

Published on: June 14, 2018

12.5K

Area of Science:

  • Biostatistics
  • Infectious Disease Diagnostics
  • Medical Device Evaluation

Background:

  • Lateral-flow antigen tests (ATs) are evaluated for sensitivity using percent positive agreement (PPA) against quantitative reverse transcription polymerase chain reaction (qRT-PCR).
  • Observed PPA is influenced by viral load distribution (inferred from cycle threshold [Ct] values), leading to biased sensitivity estimates and complicating cross-study comparisons.
  • Real-world data often lack standardized viral load sampling, deviating from regulatory guidelines and hindering accurate diagnostic test assessment.

Purpose of the Study:

  • To develop and validate a statistical methodology for recalibrating AT clinical performance data.
  • To enable accurate and comparable sensitivity assessments by standardizing viral load distributions.
  • To correct for sampling bias in diagnostic test evaluations.

Main Methods:

  • Modeled percent positive agreement (PPA) as a logistic function of qRT-PCR Ct values (PPA function).
  • Applied the PPA function to a standardized reference Ct distribution to calculate adjusted sensitivity.
  • Validated the methodology using clinical data from a community study, demonstrating reduced sampling bias.

Main Results:

  • Analyzed paired AT and qRT-PCR data from four suppliers over two years, observing significant variations in Ct value distributions.
  • Logistic regression modeling of PPA against Ct values corrected for viral load variability.
  • Adjusted sensitivity estimates provided more accurate and consistent comparisons of AT performance across suppliers.

Conclusions:

  • Introduced a distribution-aware framework for bias-corrected sensitivity estimation of ATs.
  • The method facilitates fairer, more consistent comparisons across AT suppliers and studies, enhancing quality control and regulatory review.
  • Emphasized the importance of distribution-aware evaluation for robust diagnostic test assessment.