Multi-scanner repeatability and reproducibility of qRF-MRF breath-held and free-breathing with pilot tone in the
Madison E Kretzler1, Jessie E P Sun2, Eduardo Thadeu de Oliveira Correia3,4
1Department of Radiology, Case Western Reserve University, 11100 Euclid Ave/Bolwell B115, Cleveland, OH, 44106, USA. Madison.Kretzler@case.edu.
Object:
Repeatability and reproducibility are imperative for new Magnetic Resonance Imaging (MRI) methods, such as the quantitative technique MR Fingerprinting (MRF), to be clinically adopted for regular patient usage.
Materials And Methods:
We tested the repeatability and reproducibility of a new free-breathing (FB) quadratic RF phase Magnetic Resonance Fingerprinting (qRF-MRF) with Pilot Tone (PT) navigator in the abdominal cavity with a focus on liver by performing repeat scan-rescan collection comparisons for 8 healthy volunteers on 2 different Siemens Vida 3T scanners at the same site running different software versions.
Results:
Using Bland-Altman analysis, our results for T1, T2, and T2* establish the repeatability and reproducibility, via the limits of agreement and bias estimations, of the FB qRF-MRF sequence and compare to its breath-held qRF-MRF and clinical standard counterparts across scanners and scan conditions. DISCUSSION: Based on the bias and limits of agreement of breath-hold and FB qRF-MRF patients can receive reliable and comparable imaging at different sessions for prognosis and treatment planning.
More Related Videos
08:35Oxygenation-sensitive Cardiac MRI with Vasoactive Breathing Maneuvers for the Non-invasive Assessment of Coronary Microvascular Dysfunction
Published on: August 17, 2022
08:23Author Spotlight: Advancing Lung Disease Research with Free-Breathing Hyperpolarized Xenon-129 MRI
Published on: November 10, 2023
Related Concept Videos
Assessment of Respiration
Subjective Assessment: Nurses interview the patient to gather information directly during the subjective assessment. It includes questions about the individual's medical history, medications, and symptoms, focusing on past respiratory conditions like asthma or COPD,...
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement:
Physical Assessment of the Respiratory Tract II: Palpation
Thoracic Palpation
Thoracic palpation detects tenderness, masses, lesions, respiratory excursions, and vocal fremitus. The nurse assesses...
Physical Assessment of the Respiratory Tract III: Percussion
Percussion in Respiratory Assessment
Percussion evaluates underlying tissue composition with audible and tactile vibrations,...
Respiratory System Abnormal Finding I: Inspection and Percussion
Inspection Findings
During an inspection, several findings may suggest the presence of respiratory distress or disease. Pursed-lip breathing, where exhalation is slowed by...
Respiratory System Abnormal Finding II: Palpation and Auscultation
Palpation Findings
During a respiratory assessment, palpation can reveal several vital abnormalities: