Influence of inter-fractional respiratory motion changes on dose delivery accuracy in dynamic conformal arc lung
Bong Kyung Bae1, Sung Joon Kim2, Jae-Chul Kim1
1Department of Radiation Oncology, School of Medicine, Kyungpook National University, Daegu, Korea.
Purpose:
To evaluate the influence of inter-fractional respiratory motion variation on dose delivery accuracy in dynamic conformal arc lung stereotactic body radiotherapy (SBRT) using glass dosimeter and QUASARTM respiratory motion phantom.
Materials And Methods:
Four-dimensional computed tomography (4D-CT) was acquired using a sinusoidal respiratory waveform (amplitude: 10 mm, breaths per minute [BPM]: 20). Three glass dosimeters were positioned at the superior edge, geometric center, and inferior edge of the tumor target. Internal target volume (ITV)-SBRT and gated-SBRT plans were created and delivered under nine respiratory conditions (BPM: 10-30, amplitude: 5-30 mm). Treatment was considered acceptable if the delivered dose to the glass dosimeters remained within the D5%-D95% of the gross tumor volume.
Results:
BPM had minimal effect on ITV-SBRT, with the doses delivered to the target remaining within the acceptable range for all BPMs. However, amplitude significantly affected SBRT accuracy. For ITV-SBRT, increase in amplitude caused underdose at both the superior and inferior edges. In gated-SBRT, higher amplitude led to significant underdosing at superior edge of the target than that observed in ITV-SBRT, while inferior edge remained within the acceptable dose range. Underdose worsened with increasing amplitude, and 10 mm increase from the reference caused it to fall below the acceptable range (D95%).
Conclusion:
Respiratory motion significantly affects dose delivery accuracy in lung SBRT, with amplitude playing a critical role. An amplitude increase of ≥ 10 mm from CT acquisition during SBRT delivery resulted in a significant target underdosing below the clinically acceptable threshold.
Related Concept Videos
Factors Affecting Respiration
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Respiratory Volumes
Tidal Volume (TV) Tidal volume (TV) is the air inhaled or exhaled in a...
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...