Related Experiment Video
Updated: Jan 9, 2026

Particle Image Velocimetry Investigation of Hemodynamics via Aortic Phantom
Published on: February 25, 2022
CT predicts intraprocedural hemodynamics with computational fluid dynamics in TMVR-ineligible patients undergoing
Johannes Kirchner1, Muhammed Gerçek1, Hazem Omran1
1Clinic for General and Interventional Cardiology/Angiology, Herz-und Diabeteszentrum NRW, Ruhr-Universität Bochum, Bad Oeynhausen, Germany.
Background:
Hemodynamic outcomes in patients undergoing transcatheter mitral edge-to-edge repair (M-TEER) are difficult to predict. Computational fluid dynamics (CFD) is frequently used in biomedical engineering to simulate blood flow patterns under various conditions.
Objectives:
We developed a standardized workflow for individualized CFD analyses to predict postinterventional mitral valve gradients and residual regurgitation following TEER.
Methods:
Twenty patients with severe mitral regurgitation (MR) from two high-volume centers underwent full-cycle cardiac computed tomography before intervention. Based on the specific valve morphology, individualized CFD simulations were performed to calculate MR volumes prior to intervention and estimate hemodynamics after M-TEER.
Results:
CFD analyses (mean age 80 ± 4 years, 55% male) showed excellent correlation between baseline proximal isovelocity surface area (PISA)-based MR volumes, median 40 ml [interquartile range (IQR): 30-49 ml], and CFD-based calculation, median 30 ml (IQR: 27-54 ml; R = 0.917; P < 0.001), as well as between baseline effective regurgitant orifice area (EROA) assessed in transesophageal echocardiography (TEE) and CFD-measured EROA (R = 0.869; P < 0.001). After device implantation, the correlation between intraprocedural TEE-measured and CFD-estimated residual MR (R = 0.949; P < 0.001) and EROA (R = 0.841; P < 0.001) remained robust. Median postinterventional diastolic pressure gradient (TEE) was 2.8 mmHg (IQR: 1.7-4.0), which closely correlated with the CFD-estimated gradient of 1.4 mmHg (IQR: 2.3-4.5, R = 0.905; P < 0.001).
Conclusions:
This is the first study to use a standardized CFD workflow for MR evaluation in patients undergoing TEER. In the future, CFD-based analyses may serve as a key diagnostic tool for procedural planning of TEER.
More Related Videos
09:57Four-Dimensional Computed Tomography-Guided Valve Sizing for Transcatheter Pulmonary Valve Replacement
Published on: January 20, 2022
09:36A Magnetic Resonance Imaging-based Computational Protocol for Analysis of Plaque Morphology and Hemodynamics in Patients with Carotid Artery Stenosis