Related Experiment Video
Updated: Jan 9, 2026

Non-fluoroscopic Catheter Tracking for Fluoroscopy Reduction in Interventional Electrophysiology
Published on: May 26, 2015
Zero-Fluoroscopy Ablation of Epicardial Focal Atrial Tachycardia Via the Pulmonary Artery
Minghao Zhou1, Ming Yu1, Daoyuan Si1
1Department of Cardiology, China-Japan Union Hospital of Jilin University, The Third Hospital of Jilin University, Jilin Provincial Molecular Biology Research Center for Precision Medicine of Major Cardiovascular Disease, Changchun, China.
Background:
Focal atrial tachycardia represents a common form of arrhythmia. In a subset of cases, the arrhythmogenic focus may originate from epicardial structures, which can render endocardial ablation ineffective.
Case Summary:
A 55-year-old man presented with progressive palpitations over several weeks. He had no significant prior cardiac history. During the ablation procedure, a focal atrial tachycardia refractory to conventional endocardial ablation was identified. The arrhythmia was successfully eliminated through adjunctive ablation performed within the right pulmonary artery.
Discussion:
A zero fluoroscopy transpulmonary arterial approach is feasible for ablating an epicardial atrial tachycardia, highlighting it as a viable alternative when conventional endocardial ablation fails.
Take-Home Massages:
Indirect epicardial intervention targeting the left atrium via adjacent anatomical pathways has been demonstrated to be both safe and feasible in selected cases. The performance of ablation procedures necessitates advanced catheter manipulation and can be effectively guided and localized in real time using intracardiac echocardiography.
Related Concept Videos
ECG Interpretation of Arrhythmias II: Atrial, Junctional and Ventricular Arrhythmias
Disturbances in Heart Rhythm
Arrhythmias are categorized by their speed, rhythm, and origin. A slow heart...