Related Experiment Video
Updated: Jun 16, 2026

A Silicon-tipped Fiber-optic Sensing Platform with High Resolution and Fast Response
Published on: January 7, 2019
Interferometric optical sensors based on porous silicon grafted with styrenic moieties for highly enhanced VOC
Van-The Vo1, Abhijit N Kadam2, Thuy-An Nguyen3,4
1Long Son Petrochemicals Co., Ltd, Central Laboratory Department Ho Chi Minh City Vietnam.
Abstract:
The majority of volatile organic compounds (VOCs) are hazardous pollutants that pose significant risks to human health and the environment. Thus, the development of a smart sensing system for the early identification of VOCs would be in high demand, particularly those enabling rapid detection with high sensitivity and long-term stability. In this study, an interferometric optical sensor was rationally devised through the facile non-atmospheric thermolysis of polystyrene (PS) pre-loaded into a porous silicon (pSi) template prepared via electrochemical anodization. During the thermolysis, styrenic carbon fragments were covalently grafted onto the pore walls of pSi to form a PS-grafted pSi composite (pSi-PS). This composite was subsequently utilized as a scaffold for grafting poly(4-chlorostyrene) (PPCS) via a second thermolysis step, consequently yielding the double-grafted pSi composite (pSi-PS-PPCS). The obtained samples were subsequently employed as an interferometric optical sensor for the sensitive detection of various VOCs, including ethanol, isopropanol, isobutanol, n-hexane, methyl ethyl ketone (M. E. K.), and ethyl acetate. The sensitivity of the optical response to those VOCs exhibited the following order: n-hexane < ethanol < isopropanol < M. E. K. < isobutanol < ethyl acetate. Notably, the double-grafted pSi-PS-PPCS sensor exhibited significantly higher sensitivity than both pristine pSi and single-grafted pSi-PS. The highly enhanced sensitivity of pSi-PS-PPCS, particularly toward isobutanol and ethyl acetate vapors, was mainly attributed to strong intermolecular interactions (such as hydrophobic, hydrogen bonding effects and/or strong interplay of π-π interactions) between the VOC analytes and the chlorine-substituted phenyl moieties of the grafted PPCS.
Related Concept Videos
Gas Chromatography: Types of Detectors-II
High-Performance Liquid Chromatography: Types of Detectors
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
UV–Vis Spectrometers
High-Performance Liquid Chromatography: Instrumentation