Related Experiment Video
Updated: Jan 9, 2026

Author Spotlight: Evaluating Clinicians' Adoption of Ultrasound-Guided Vascular Cannulation Through Simulation Training
Published on: August 9, 2024
Assessing the Influence of a Statewide Dosing Reference Aid on Prehospital Pediatric Medication Dosing Errors: A
Bryan M Harmer1, John D Hoyle2, Autumn Edwards3
1Department of Paramedicine, College of Nursing, Creighton University, Omaha, Nebraska.
Objectives:
Errors occur in 31% of prehospital pediatric medication administrations (PMA) in Michigan despite the implementation of the MI-MEDIC pediatric dosing reference aid. Reference aids may not effectively target the causes of dosing errors and could introduce new types of error. Our study examines the frequency, magnitude, and immediate causes of PMA dosing errors in emergency medical services (EMS) after implementation of the MI-MEDIC dosing reference aid.
Methods:
We used a mixed method, mobile simulation-based approach to examine PMA dosing errors. Emergency medical services crews were recruited from a private EMS service and a fire-based EMS service in Michigan. Each crew completed three high-fidelity simulations (infant seizure, infant cardiac arrest and child burn) requiring two doses of midazolam, epinephrine, or fentanyl. Post-simulation interviews were conducted. Error rates and magnitudes were analyzed using descriptive statistics. A multidisciplinary team used a modified Delphi method, incorporating simulation observations, interview recordings, pictures of equipment that were used during the simulations, and protocols to categorize observed errors and reach consensus on their immediate causes.
Results:
Eleven crews were recruited between both agencies, completing 33 simulations and 66 medication administrations, using the MI-MEDIC dosing reference aid. Dosing errors occurred in 19 of the 66 doses (28.8%), with 13 underdoses (68.4%) and six overdoses (31.6%). The median underdose was 0.50 (95% IQR: 0.20-0.56). The median overdose was 2.00 (95% IQR: 1.40-12.50). After two rounds, Delphi consensus categorized 13 slips (68.4%), six mistakes (31.6%), and no lapses. Immediate causes included crews obtaining the wrong weight (4/19, 21.0%), a large volume of air present in the syringe (6/19, 31.6%) and improper dilution of medications when following instructions on the MI-MEDIC reference aid (6/19, 31.6%). The remaining three involved epinephrine administration directly from the prefilled syringe system (2/19, 10.5%) and an intentional underdose (1/19, 5.3%).
Conclusions:
PMA dosing errors persist at a high rate with the use of the MI-MEDIC dosing reference aid. Immediate causes of error involve incorrect weight, administering air, and improper dilution, which tools like the MI-MEDIC dosing reference aid do not address. Further research is needed to develop comprehensive strategies addressing the active errors identified in our study.
Insights
Prehospital pediatric medication errors persist despite a dosing reference aid. Common errors include incorrect weight, air in syringes, and improper dilution, indicating a need for improved strategies.
Area of Science:
- Emergency medicine
- Pediatric critical care
- Medication safety
Background:
- Prehospital pediatric medication administrations (PMA) have a high error rate (31%) in Michigan.
- Existing reference aids like MI-MEDIC may not fully address the root causes of these dosing errors.
Purpose of the Study:
- To investigate the frequency, magnitude, and immediate causes of PMA dosing errors.
- To evaluate the effectiveness of the MI-MEDIC pediatric dosing reference aid in reducing errors.
Main Methods:
- A mixed-method, simulation-based approach was used with emergency medical services (EMS) crews.
- High-fidelity simulations of pediatric emergencies were conducted, requiring medication administrations.
- Post-simulation interviews and a modified Delphi method were employed to analyze errors and their causes.
Main Results:
- Dosing errors occurred in 28.8% of administrations, with underdosing being more frequent (68.4%).
- Median underdose was 0.50, and median overdose was 2.00.
- Identified causes included incorrect weight (21%), air in syringes (31.6%), and improper medication dilution (31.6%) per the reference aid.
Conclusions:
- High rates of PMA dosing errors persist even with the MI-MEDIC reference aid.
- Current aids do not address critical error sources like incorrect weight, air in syringes, or dilution issues.
- Further research is needed to develop comprehensive strategies to mitigate identified active errors in pediatric medication safety.
More Related Videos
06:59A Novel Approach for the Administration of Medications and Fluids in Emergency Scenarios and Settings
Published on: November 9, 2016
09:52Setting Up a Stroke Team Algorithm and Conducting Simulation-based Training in the Emergency Department - A Practical Guide
Published on: January 15, 2017
Related Concept Videos
Drug Dosing: Infants and Children
Dosage Regimens: Designs and Approaches
Dosage Regimens: Partial Pharmacokinetic Parameters
Dose Size and Dosing Frequency: Determination Methods
Determination of Multiple Dosing Parameters: Loading and Maintenance Doses
Pharmacokinetics in Pediatric Patients: Drug Distribution