Analysis of Volatile and Oxidation Sensitive Compounds Using a Cold Inlet System and Electron Impact Mass Spectrometry
Published on: September 5, 2014
Variability in the Universality of Electron Ionization Mass Spectrometry Response to Oxygenates in Complex
Purushottam Kumar1, Chenyang Bi2, Brian Lerner2
1Department of Civil and Environmental Engineering, Virginia Tech, Blacksburg, Virginia VA-24061, United States.
Abstract:
Electron ionization mass spectrometry (EIMS) has been widely used to measure complex atmospheric and environmental mixtures. The sensitivity of analytes in EIMS is typically obtained through a multipoint calibration curve using commercially available standards, but many analytes of interest do not have pure compounds available, and many samples contain a large fraction of unidentified compounds. To address these limitations in quantification, those analytes are often calibrated using a small number of standards with chemical similarities (e.g., shared functional groups). However, little systematic data are available on the variability of EIMS response factors to environmental analytes. In this work, we compare the EIMS response with a flame ionization detector (FID), a near-universal detector for organics, to quantify the variability in EIMS sensitivity to organics in a complex atmospheric mixture, particularly secondary organic aerosols (SOA). Particle-phase oxidation products from four precursor-oxidant pairs were produced, sampled, and analyzed by gas chromatography using a Thermal Desorption Aerosol Gas Chromatograph (TAG) with simultaneous detection by both FID and EIMS. The signals of FID and EIMS are highly correlated across the chromatogram, and peak areas of individual chromatographic peaks measured by both detectors are also closely correlated. The sensitivity of EIMS varies on average by ∼21% relative to FID for peak-by-peak comparison of oxygenated organic compounds within a complex mixture, suggesting that as long as some information is available about an unknown sample to categorize the analytes in the sample, an EIMS can be treated as a universal detector calibrated using chemically similar analytes.
More Related Videos
08:23Analyzing the Photo-oxidation of 2-propanol at Indoor Air Level Concentrations Using Field Asymmetric Ion Mobility Spectrometry
Published on: June 14, 2018
09:38Single-throughput Complementary High-resolution Analytical Techniques for Characterizing Complex Natural Organic Matter Mixtures
Published on: January 7, 2019
Related Concept Videos
Mass Spectrometry: Overview
Mass Spectrometry: Isotope Effect
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences
Mass Spectrum: Interpretation
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Mass Spectrometry: Molecular Fragmentation Overview
One type of fragmentation pattern is the cleavage of a single bond in the molecular ion. The cleavage leads to a radical and a cation. The cleavage can occur at...