Background:
The Urea Breath Test (UBT) is the golden standard of investigation for Helicobacter pylori. Tuberculosis is common and endemic in Iraq, with limited investigations. This study was conducted to determine the safety and importance of UBT as a method for the diagnosis of active pulmonary tuberculosis.
Material And Method:
A prospective, case-control study trial was conducted to determine the safety of 75 mg of inhaled C13-urea in 50 healthy participants. Then, in national TB, Over the course of a one-year study at a medical city in Baghdad, 50 participants with confirmed active pulmonary tuberculosis were enrolled. The safety of inhaled C13-urea was assessed by physical examination and spirometry. The C13-urea was administered by using a jet nebulizer, followed by the collection of exhaled breath at 15 and 30 min' post-inhalation. A double-beam infrared spectrophotometer examined the isotopic ratio of (C13) CO2 to (C12) CO2.
Results:
The lung function test, which included forced vital capacity (FVC) and forced expiratory volume in 1 s (FEV1), did not show any changes that were clinically significant when healthy people and people with pulmonary tuberculosis (PTB) were compared to their baseline values. Additionally, there was no recorded incidence of adverse events among both healthy individuals and those with pulmonary tuberculosis (PTB). After 15 min of the nebulization process, the delta over baseline (DOB) means of the control group and PTB patients were -1.2381 ± 1.8392 and 4.8215 ± 5.1889, respectively. After 15 min of the nebulization process, the DOB means of the control group and PTB patients were -1.9628 ± 3.0717 and 3.5686 ± 3.8484, respectively.
Conclusion:
Inhaling 13 C-urea seemed safe. DOB values in PTB patients were greater than in controls. Preliminary data suggest that DOB values at 15 min were higher than 30 min. This has potential for diagnosing Mycobacterium tuberculosis.
Related Concept Videos
Pulmonary Tuberculosis IV
Several diagnostic approaches are used to detect TB. The conventional method is the Tuberculin Skin Test (TST), also known as the Mantoux test. However, this method has...
Serum Laboratory Studies, Stool Test, Breath Test
¹³C NMR: Distortionless Enhancement by Polarization Transfer (DEPT)
Pulmonary Function Tests
Pulmonary Function Tests are crucial diagnostic tools for assessing respiratory function, particularly in patients with chronic respiratory disorders. They comprehensively evaluate lung volumes, ventilatory function, breathing mechanics, diffusion, and gas exchange. These tests help diagnose pulmonary diseases and play a significant role in monitoring disease progression, evaluating disability, and assessing response to therapy.
PFTs involve using a spirometer, a...
Pulmonary Tuberculosis III
The first classification is based on the development of the disease, and it includes the following categories:
Pulmonary Tuberculosis V
Latent tuberculosis infection occurs when TB bacteria are present in a person's body, but are not causing illness or symptoms. It is not contagious, and preventive treatment is crucial to avoid the...