Enhancing CBCT-based CT synthesis using planning MRI in adaptive proton therapy for head cancer: A deep learning
Juan Manuel Molina-Maza1, David Viar-Hernandez1, Blanca Rodriguez-Gonzalez1
1Universidad Rey Juan Carlos, Medical Image Analysis and Biometry Laboratory, Madrid, Spain.
Background:
Proton therapy (PT) is recognized as a superior treatment for head cancer (HC) due to its precision and minimal damage to surrounding healthy tissues, relying on computed tomography (CT) data for dose calculations. Adaptive proton therapy (APT) is crucial to address changes in patient anatomy during treatment and update dose accuracy. However, in-room cone-beam CT (CBCT) assistance is limited to assessing patient setup, with occasional constraints due to artifacts and/or lower image quality and resolution compared to a CT scan.
Purpose:
Although deep learning (DL) techniques can successfully convert a CBCT into a synthetic CT (sCT), soft tissue delineation remains a challenging task. We hypothesized that, by including Magnetic Resonance Image (MRI) in CBCT-based CT synthesis, the sCT generation could more closely approximate the CT ground truth while improving tissue definition and dose calculation in PT treatment planning.
Methods:
We propose a Pix2Pix-conditional generative adversarial network (cGAN) to synthesize a CT scan by combining two different input images: CBCT and T1-weighted MRI. ResUnet and SwinUnet were evaluated as the cGAN generator. Additionally, a CBCT-only-based CycleGAN was tested.
Results:
Model performance improved with the inclusion of MRI data, especially in recovering soft tissue details like eyes and ventricles, with ResUnet models outperforming SwinUnet models. Our cGAN outperformed both the self-autoencoder approaches and the CycleGAN model. Pix2Pix-ResUnet (MR-based) significantly reduced average HU errors in volumes of interest and also enhanced the precision in dose values, as demonstrated in dose differences and profiles.
Conclusions:
We demonstrated the promising contribution of MRI to CBCT-based CT synthesis, enhancing sCT image quality and dose calculation accuracy. Future efforts should aim to collect a larger dataset and validate the integration of MRI in APT.
More Related Videos
08:34Proton Therapy Delivery and Its Clinical Application in Select Solid Tumor Malignancies
Published on: February 6, 2019
07:57Positron Emission Tomography-based Dose Painting Radiation Therapy in a Glioblastoma Rat Model using the Small Animal Radiation Research Platform
Published on: March 24, 2022
Related Concept Videos
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Brain Imaging
These technologies include computerized axial tomography (CAT or CT scans), positron-emission tomography (PET scans), magnetic resonance imaging (MRI), functional magnetic resonance imaging (fMRI), and Transcranial Magnetic...