Related Experiment Video
Updated: May 6, 2026

Home-Based Monitor for Gait and Activity Analysis
Published on: August 8, 2019
From Static to Dynamic: Complementary Roles of FSR and Piezoelectric Sensors in Wearable Gait and Pressure Monitoring
Sara Sêco1, Vítor Miguel Santos2, Sara Valvez2
1University of Coimbra, Department of Physics, 3040-516 Coimbra, Portugal.
Objective:
Plantar pressure abnormalities have a significant impact on mobility and quality of life. Real-time pressure monitoring is essential in clinical and rehabilitation settings for assessing patient progress and refining treatment protocols. Instrumental and particularly smart insoles offer a promising solution by collecting biomechanical data during daily activities. However, determining the optimal combination of sensor type, number, and placement remains a key challenge for ensuring accurate and reliable measurements. This study proposes a methodology for identifying the most appropriate sensor technology for wearable insoles, with a focus on data accuracy, system efficiency, and practical applicability. Additionally, it examines the correlation between sensor signals and material behavior during compression testing.
Methods:
Two insole prototypes underwent compression testing: one equipped with a Force Sensitive Resistor (FSR) sensor and one with a piezoelectric sensor, both positioned at the heel. Three trials per prototype assessed consistency and repeatability. Real-time data acquisition utilized a microcontroller system, and signals were processed using a sixth-order Butterworth low-pass filter with a 5 Hz cutoff frequency to reduce noise.
Results:
FSR sensors demonstrated stable static responses but saturated rapidly beyond 20 N, with performance degradation observed after repeated loading cycles. Piezoelectric sensors exhibited excellent dynamic sensitivity with sharp voltage peaks but proved unable to measure sustained static pressure.
Conclusions:
FSR sensors are well-suited for static postural assessment and continuous pressure monitoring, while piezoelectric sensors excel in dynamic gait analysis. This comparative framework establishes a foundation for developing future smart insole systems that deliver accurate, real-time rehabilitation monitoring.
More Related Videos
Related Concept Videos
Static and Kinetic Frictional Force
However, if two systems are in contact and are stationary relative to one...
Magnetic Damping
If, however, the bob is a slotted metal plate, the magnet produces a much smaller effect. When a slotted metal plate enters the field, an emf is induced by the change in flux; however, it is less effective because the slots limit the...
Static Friction
For example, consider a scenario where a truck is connected to a car by a rope, ready to tow it along a road. When no external force is applied by the truck, the car remains stationary and is said to be in static equilibrium. In this case, the forces acting on the car, such as gravity and the...
Pressure Gauges
Measurement of Fluid Pressure
A basic form of manometer is the piezometer, a vertical tube open at the top and filled with the same...
Static, Stagnation, Dynamic and Total Pressure