Multiscale vibration response analysis and fatigue damage prediction after idiopathic scoliosis kyphosis surgery
Yuxuan Zhang1, Rongchang Fu1, Pengju Li1
11School of Mechanical Engineering, Xinjiang University, Urumqi, Xinjiang, China.
Abstract:
Purpose: The aim of this study was an exploration of the multiscale vibratory response of the spine following orthopedic surgery in patients with idiopathic scoliosis and postoperative traumatic fatigue injury. Methods: In this paper, the postoperative macroscopic spine model in the modal, time and frequency domains to obtain the vibration response of the patient's entire spine were analyzed. Subsequently, the stresses in the cortical bone mesoscopic bone units around the surgically damaged interface were calculated using submodeling algorithms. The pore stresses and pore flow velocities of the osteocytes were then derived from the stresses of the mesoscopic bone units to predict fatigue damage at the fusion surface. Results: The findings indicated that the first three orders of intrinsic frequency exerted the most significant influence on the spine model. The maximum stress of the bone unit was observed at the X3 bone plate on the left side of the fusion surface, and the maximum pore pressure and flow velocity of the bone cells occurred at the X4 on the right side of the fusion surface. The medical implants used in spinal orthopedics, titanium cages and pedicle nails, change the mobility of the adjacent segments and also create a stress shielding effect that impacts the fusion of bone tissues. Conclusions: Microscopic bone cell synapses experience greater pore pressures and pore flow velocities in the vibration environment compared to those under the static environment, which may promote cell growth. Vibration at low loads typically does not induce fatigue damage to cancellous bone at the fusion surface of medical implants.
More Related Videos
08:08Cell-based Assay Protocol for the Prognostic Prediction of Idiopathic Scoliosis Using Cellular Dielectric Spectroscopy
Published on: October 16, 2013
07:44Evaluation of Patients' Posture and Gait Profile After Lumbar Fusion Surgery by Video Rasterstereography and Treadmill Gait Analysis
Published on: March 23, 2019
Related Concept Videos
General Case of Eccentric Axial Loading
Consider a member subjected to equal and opposite forces that are applied along a line that does not coincide with the member's neutral axis. In unsymmetrical...
Deformation of Member under Multiple Loadings
In the case of a member with a variable cross-section, the strain is not constant but depends on the position. The deformation of an...
Bending of Curved Members - Strain Analysis
The important part of bending analysis for such a member...
Normal Strain under Axial Loading
Eccentric Axial Loading in a Plane of Symmetry