Related Experiment Video
Updated: Jan 8, 2026

A Simple and Scalable Fabrication Method for Organic Electronic Devices on Textiles
Published on: March 13, 2017
Highly Sensitive Thermoelectric Fabric of PEDOT:PSS/SWCNT@PU Composite Fibers for Body-Temperature Monitoring and
Pan Luo1, Shuyuan Dong1, Lirong Liang1
1College of Materials Science and Engineering, Shenzhen University, Shenzhen, 518055, P. R. China.
Abstract:
Integrated flexible thermoelectric (TE) fabric demonstrates great potential for wearable energy harvesting and intelligent temperature sensing. However, existing TE fibers often struggle to simultaneously satisfy requirements for high and stable TE performance, favorable weavability, sweat resistance, and good biocompatibility. Herein, continuous PEDOT:PSS/SWCNT composite fibers with these desirable features are obtained via a convenient freeze-thaw-induced gelation process assisted wet-spinning process, exhibiting a high electrical conductivity of 1960 S cm-1, a large power factor of 59.6 µW m-1 K-2, and a high tensile strength of 103 MPa. Polyurethane-encapsulated composite fibers further provide superior mechanical flexibility, desirable weavability, remarkable washability, low-temperature tolerance, and stable TE performance over 1000 bending/twisting cycles. A resulting TE fabric comprising 32 p-type legs achieves a power density of 60.1 µW cm-2 at temperature difference of 50 K, surpassing most reported PEDOT:PSS-based fiber devices, and retains over 95% performance after various mechanical deformations. The developed fabric-integrated intelligent fever monitoring system (forehead/wrist/armpit) exhibits high sensitivity (alarm response < 5 s) and good repeatability (3-4.3 s response over 50 cycles) for low/high fever monitoring. Such composite TE fibers are anticipated to advance practical applications of wearable TE fabrics in body energy harvesting, personalized healthcare, and intelligent fitness monitoring.
Related Concept Videos
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...
Thermosensation
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...