Assessment of Intra- and Intercapillary Variability in HbA1c Measurement Using the Sebia Capillarys OCTA3 Analyzer

Meriem Belhedi1, Wiem Lazzem1, Othman Bacha1

  • 1Department of Laboratories, Habib Thameur's Hospital, Tunis, Tunisia.

Electrophoresis
|December 15, 2025
PubMed

Hemoglobin A1c (HbA1c) measurement is crucial for diabetes monitoring. Validation of analytical methods ensures the reliability of results. We verified the analytical performance of HbA1c measurement in each capillary of the Capillarys OCTA3 automated capillary analyzer, following the French accreditation committee guide. For each capillary and each HbA1c level, we evaluated repeatability, intermediate precision, accuracy, robustness, and measurement uncertainty. Results were compared to acceptance limits from French Society of Clinical Biology (SFBC), European Federation of Clinical Chemistry and Laboratory Medicine (EFLM), Réseau d'identification et de Communication en Oncologie et Sénologie (RICOS), and Clinical Laboratory Improvement Amendments (CLIA). A comparison with the high-performance liquid chromatography (HPLC) method was performed on 37 samples using linear regression and Bland-Altman analysis. Repeatability coefficient of variations (CVs) were less than 1.1% for both levels, consistent with supplier and SFBC (3.8%) thresholds. Precision CVs were 1.24% (normal) and 1.3% (pathological), below SFBC and supplier limits but above the strict EFLM standard. Accuracy showed consistent biases between 0% and 1.02%. Method comparison showed acceptable agreement. Expanded uncertainties were 3.10% (normal) and 2.89% (pathological), exceeding EFLM recommendations (1.8%). Westgard and CLIA sigma indices confirmed satisfactory robustness; EFLM indices were lower for some capillaries, limiting Six Sigma use. The OCTA3 analyzer demonstrated excellent analytical performance. Individual capillary verification yielded satisfactory results. Despite uncertainty exceeding EFLM recommendations and variable robustness, this method is reliable for routine clinical use.

Related Concept Videos

Capillary Electrophoresis: Instrumentation01:20

Capillary Electrophoresis: Instrumentation

Capillary electrophoresis instrumentation typically consists of several key components. A high-voltage power supply generates the electric field necessary for the separation by connecting to an anode (the positively charged electrode) and a cathode (the negatively charged electrode) located in buffer reservoirs at each end of the capillary tube. The system includes a sample vial, a fused silica capillary tube coated with polyimide for mechanical strength through which the sample components...
878
Assessment of blood pressure in brachial artery(two-step method)01:23

Assessment of blood pressure in brachial artery(two-step method)

Measuring blood pressure is a fundamental skill in healthcare that aids in diagnosing and monitoring hypertension and other cardiovascular conditions. An aneroid sphygmomanometer, commonly used in clinical settings, offers a manual and precise method for blood pressure measurement. The technique for using this instrument involves specific steps that must be carefully executed to ensure accuracy. The following detailed description outlines a two-step technique for assessing blood pressure using...
1.4K
Variability: Analysis01:11

Variability: Analysis

Measures of variability are statistical metrics that reveal the dispersion pattern within a dataset. They are pivotal in biostatistics, providing insights into the heterogeneity within health and biological data. Variability signifies the degree to which data points diverge from one another, helping researchers understand the potential range of values and associated uncertainty within the data.
The range is a simple measure of variability, indicating the difference between the highest and...
421
Assessment of blood pressure in brachial artery(one-step method)01:15

Assessment of blood pressure in brachial artery(one-step method)

This procedural guide systematically measures blood pressure using an oscillometric digital sphygmomanometer, emphasizing accuracy, patient safety, and comfort.
Prepare for the Procedure:
1.1K
Capillary Electrophoresis: Applications01:30

Capillary Electrophoresis: Applications

Capillary electrophoretic separations offer various modes, each with unique applications. These modes include capillary zone electrophoresis, capillary gel electrophoresis, capillary array electrophoresis, capillary isoelectric focusing, capillary isotachophoresis, micellar electrokinetic chromatography, and capillary electrochromatography.
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
1.1K