Evaluating commercial multimodal AI for diabetic eye screening and implications for an alternative regulatory pathway
Matthew S Hunt1, Tinglong Dai2,3,4, Michael D Abràmoff5,6,7
1Department of Ophthalmology and Visual Sciences. University of Iowa, Iowa City, IA, USA.
None:
Autonomous AI for diabetic eye examination is among the most validated and trusted medical AI systems, supported by extensive real-world evidence demonstrating safety, efficacy, improved outcomes, increased productivity, and cost savings. Yet its adoption remains limited. In contrast, commercially available off-the-shelf generative AI models (OTSAIs) are being rapidly tested in medical settings despite a lack of such real-world validation. These models have shown strong performance on medical reasoning tasks, prompting interest in their potential for clinical deployment. We evaluated four OTSAIs-GPT-4o and GPT-4o-mini (OpenAI, San Francisco, CA), Grok (xAI, San Francisco, CA), and Gemini (Google, Mountain View, CA)-on a specific diagnostic task: diabetic eye examination. The OTSAIs were bundled to ensure consistency, and performance was assessed using a level 3 reference standard, the publicly available Messidor-2 dataset. GPT-4o achieved the highest area under the receiver operator characteristic curve (AUC), 0.83. Grok achieved 0.63, and AUC was not calculable for Gemini. The AUC of retina specialists on the same task was estimated at 0.94, so the emergent performance of OTSAIs does not match that of clinical experts, nor does it approach FDA endpoints for consideration as a medical device. Nevertheless, as the performance of these OTSAIs approaches theoretical limits in the future, there might be a regulatory path through task-specific licensing by State Medical Boards for specific clinical tasks. This path may be modeled after licensing for physician assistants, where trust in the bundled OTSAI, to be used in an assistive fashion, is achieved through rigorous validation for safety and efficacy according to widely accepted regulatory considerations for both patient-facing AI, as well as for SaMD processes.
More Related Videos
07:41Behavioral Assessment of Visual Function via Optomotor Response and Cognitive Function via Y-Maze in Diabetic Rats
Published on: October 23, 2020
10:14Author Spotlight: Ex Vivo OCT-Based Multimodal Imaging of Human Donor Eyes for Research into Age-Related Macular Degeneration
Published on: May 26, 2023