Related Experiment Video
Updated: Jan 8, 2026

A Simple Critical-sized Femoral Defect Model in Mice
Published on: March 15, 2015
Percutaneous Fracture Reduction of Cadaveric Feline Tibiae (Gap Model) Using Computed Tomography, Computer Design
Felix Marten1, Sabine Kramer1, Nikolaus Huels1
1Klinik für Kleintiere, Stiftung Tierärztliche Hochschule Hannover, Hannover, Germany.
Objective:
This study aimed to evaluate percutaneous reduction of feline tibial fractures (gap model) using a three-dimensional-printed external skeletal fixator (jig) and assess the contralateral tibia as a template for virtual planning.
Study Design:
Postmortem computed tomography (CT) was performed on 11 skeletally mature feline specimens. A mid-shaft tibial fracture gap model was created, followed by the placement of two lead-marked K-wires per fragment. The DICOMS images of repeated CT scans were imported into the virtual planning software to design a specimen-specific jig using the contralateral side as a template. The jig housed the leads and acted as a connecting bar to facilitate fracture reduction. Post-procedure radiography and CT were performed to evaluate fracture reduction.
Results:
A total of 22 tibiae of 11 cats were reduced using a jig. There was an average difference of <1 mm in terms of tibial length and <5 degrees in joint angulations and in terms of rotation when comparing the post-procedure tibia with the initial CT/radiograph (p < 0.05). The alignment was considered anatomical in 16 of 21 limbs and acceptable in 5 of 21 limbs. Pin loosening occurred in one case during the jig process.
Conclusion:
Temporary fracture reduction using the three-dimensional-printed jig was feasible and accurate in 21 of the 22 procedures. When using the contralateral tibia as a template, an asymmetry of up to 6% in terms of joint angulations should be considered.