Comparison of image quality in carotid dual-energy computed tomography angiography at 55 keV virtual monoenergetic
Xiaohan Liu1, Chong Wang1, Juan Long1
1Department of Radiology, the Affiliated Hospital of Xuzhou Medical University, Xuzhou, Jiangsu, China.
Objectives:
This study aims to evaluate the image quality of 55 keV virtual monoenergetic imaging (VMI) in carotid dual-energy computed tomography (CT) angiography (DE-CTA) reconstructed using deep learning image reconstruction (DLIR) algorithms and traditional iterative reconstruction algorithms.
Material And Methods:
This prospective study included 48 patients who underwent DE-CTA examinations at our institution between December 2024 and January 2025. Image reconstructions were performed using 50% strength adaptive statistical iterative reconstruction-Veo (ASIR-V 50%), low and high strengths DLIR (DLIR-L and DLIR-H) algorithms. Objective image quality was evaluated by measuring background noise (standard deviation), signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) at key anatomical locations, including the aortic arch, common carotid artery, carotid bifurcation, and internal carotid artery. Two senior radiologists conducted subjective assessments of image quality, focusing on image noise, artifacts, and vessel continuity, and the clarity of vascular wall margin.
Results:
Compared with ASIR-V 50% and DLIR-L, DLIR-H significantly improved image quality by reducing background noise and increasing SNR and CNR (P < 0.05). Subjectively, DLIR-H images demonstrated better suppression of noise and clearer vascular wall margin (P < 0.05). Subgroup analysis revealed that these improvements were more pronounced in patients with a body mass index (BMI) ≥24 kg/m2. No significant differences were observed in CT attenuations among the three reconstruction methods (P > 0.05).
Conclusion:
At 55 keV VMI in carotid DE-CTA, DLIR-H significantly enhanced image quality, particularly by reducing noise and preserving fine anatomical structures. Its efficacy was especially notable in patients with BMI ≥24 kg/m2.
More Related Videos
05:32Retrospective Cardiac Gating with A Prototype Small-Animal X-ray Computed Tomograph
Published on: February 21, 2025
09:36A Magnetic Resonance Imaging-based Computational Protocol for Analysis of Plaque Morphology and Hemodynamics in Patients with Carotid Artery Stenosis
Published on: August 12, 2025
Related Concept Videos
Imaging Studies for Cardiovascular System V: CT
Imaging Studies III: Computed Tomography
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies VII: Vascular Imaging
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...