Aortopulmonary fistula following mitral valve replacement: a case report
Nágila Simon Ziebell1, Luiz Felipe Perin1, Raul Rossi Filho1
1Department of Cardiology, Instituto de Cardiologia (IC/FUC), Porto Alegre, Rio Grande do Sul, Brazil.
None:
Acquired aortopulmonary fistula is a rare condition that may cause heart failure symptoms secondary to high-output pulmonary overload. We report an unusual case of an aortopulmonary fistula secondary to an aortic injury sustained during mitral valve replacement, which was identified during follow-up because of recurrent heart failure symptoms and repeated hospital admissions. Multimodality imaging enabled precise characterization of the fistula. After a Heart Team discussion, percutaneous closure was selected as the preferred treatment strategy. Based on the assessment of the trajectory and morphology of the fistula, a patent ductus arteriosus (PDA) occluder was chosen. Although the ostium of the fistula was challenging to identify, successful closure was achieved using the PDA occluder.