Investigating object detection errors in endoscopic imaging of esophageal SCC and dysplasia through precision-recall
Li-Jen Chang1,2, Kun-Hua Lee3,4, Arvind Mukundan4,5
1Division of Gastroenterology and Hepatology, Department of Internal Medicine, Ditmanson Medical Foundation Chia-Yi Christian Hospital, Chiayi, Taiwan.
Introduction:
Esophageal squamous cell carcinoma (ESCC) is difficult to detect early on white-light endoscopy (WLI) because lesions are subtle and artifacts (such as glare, bubbles, text, tools) mimic pathology.
Methods:
This study benchmarked five object detectors including two You Only Look Once models (YOLOv5, YOLOv), Faster Region-based Convolutional Neural Networks (Faster R-CNN), Single Shot MultiBox Detector (SSD) and Real-time Detection Transformer (RT-DETR) on WLI dataset using harmonized training (from scratch, 150 epochs, identical hyperparameters) and two label configurations: a 4-label as major categories (SCC, Dysplasia, Bleeding, Inflammation) and an 11-label artifact. Evaluation used macro precision/recall/F1 at IoU 0.50 on a fixed 310-image test set.
Results:
Incorporating artifact classes improved overall macro metrics, with YOLOv5/YOLOv8 providing the strongest performance in the 11-label scenarios, however, class-wise findings revealed persistent recall limitations for early disease. In the 11-label analysis, Dysplasia detection remained low (YOLOv5: 88/201, 43.8%; YOLOv8: 82/201, 40.8%), and SCC was only moderate (YOLOv5: 25/44, 56.8%; YOLOv8: 24/44, 54.5%). Confusion analyses showed that errors were dominated by non-detections ("background") rather than misclassification with benign or artifact labels, while approximately one in five lesion predictions was a spurious unmatched false positive, implicating both sensitivity and specificity constraints.
Discussion:
These results indicate that labeling artifacts reduces non-lesion confusion but does not, by itself, recover subtle early lesions. Limitations include single-center, WLI-only data and training from scratch, future work should prioritize endoscopy-specific pretraining, explicit artifact suppression or joint segmentation, and external validation.
Related Concept Videos
Endoscopic Procedures I: Esophagogastroduodenoscopy
During an EGD, the endoscope can be used to:
Barrett Esophagus-I: Introduction
This constant acid exposure transforms the esophagus's pink mucosal lining (stratified squamous epithelium) into a type of lining more...
Endoscopic Procedures III: Video Capsule Endoscopy
Endoscopic Studies I: Bronchoscopy and Thoracoscopy
Bronchoscopy
Description
Bronchoscopy is a procedure that involves direct visualization of the larynx, trachea, and bronchi for diagnostic and therapeutic purposes. A flexible fiber optic or rigid bronchoscope is used to carry out the procedure. The fiber-optic bronchoscope is more frequently used due...