Related Experiment Video
Updated: Jan 8, 2026

Generation and Coherent Control of Pulsed Quantum Frequency Combs
Published on: June 8, 2018
Frequency-Amplitude Dual-Parameter-Modulated on a Single WE-QCM-D for VOCs Discrimination and Analysis
Changle Pei1, Muhammad Hamza Nadeem1, Nan Li2
1State Key Laboratory of Industrial Control Technology, Institute of Cyber Systems and Control, College of Control Science and Engineering, Zhejiang University, Hangzhou 310027, China.
Abstract:
The complexity of in situ volatile organic compounds (VOCs) detection demands high selectivity and anti-interference capability of electronic noses (E-noses). Multivariant virtual sensor array (VSA) is a new generation of E-noses under research to overcome the insufficient VOCs selectivity limitation of existing electronic noses and alleviate the issue of sensor drifts. In this paper, a frequency-amplitude dual-parameter modulation strategy is presented on a wireless electrodeless quartz crystal microbalance with dissipation (WE-QCM-D) to realize the recognition and analysis of VOC mixtures and complex real-world analytes with a single multivariant VSA E-nose, by probing the gas dynamic sorption in a sensitive film at various scales of oscillating shear displacements and obtaining multiple partially independent responses to VOCs. Ten VOC analytes from alcohols, esters, and aromatic hydrocarbons were classified with accuracies of above 95% for both interclass and intraclass discriminations. Additionally, a discriminating accuracy of 95% has been achieved on VOC mixtures, and their component concentrations were predicted with coefficients of determination above 0.9. For practical testing, the system was exposed to the headspace VOCs of banana, pineapple, and mango under different concentrations. It recognized different fruits and identified the ripen state of bananas based on the detection of their volatiles. The dual-parameter modulated WE-QCM-D paves a promising multivariant way to realize online real-time VOCs monitoring with high performance on selectivity and quantitative analysis.
Related Concept Videos
IR Spectrum Peak Splitting: Symmetric vs Asymmetric Vibrations
Wave Parameters
Pulse amplitude and quality
A weak or absent pulse may indicate reduced cardiac output or poor left ventricular contraction, which can be signs of cardiovascular dysfunction or...
Frequency-Domain Interpretation of PD Control
The proportional control gain, combined with the...
Double Resonance Techniques: Overview
Spin decoupling is usually achieved by...
Design Example

