Related Experiment Video
Updated: Jan 8, 2026

Author Spotlight: The Box-Cavity Cortical Approach for Enhanced Evaluation of Biomaterials and Bone Regeneration
Published on: November 21, 2023
Automated and manual model creation workflows are equally reliable for virtual mechanical testing of ovine bone and
Mehran Bahrami1, Alireza Ariyanfar1, Karina Klein2
1Mechanical Engineering & Mechanics, Lehigh University, Packard Lab Room 356 19 Memorial Drive West, Bethlehem, PA, 18015, USA.
Abstract:
Virtual mechanical testing on image-based bone models (digital twins) provides subject-specific insights about the mechanical behavior of a bone during fracture healing. However, the established workflows for these tests are limited by reliance on commercial software and time-consuming manual procedures needed to create the digital twins. To overcome these barriers to clinical adoption and scalability, we have developed methods for user-independent and automated model generation. This study aimed to: (1) compare four competing methods for digital twin creation (two manual versus two automated approaches), (2) assess the influence of model-creation procedures and choice of material model (single- and dual-zone) on the virtual test results, and (3) evaluate the accuracy of the model-creation techniques through experimental validation of the results. Digital twins were generated from 59 CT scans (33 operated osteotomy fractures, 26 contralateral intact bones). Torsional rigidities were compared between modeling workflows and validated using postmortem physical mechanical test data. There were no significant differences in torsional rigidity between any of the four virtual testing groups and physical testing when a dual-zone material model was implemented for bone and callus. These results confirm that virtual mechanical testing is a reliable alternative to physical mechanical testing for assessing intact and healing long bones, with resilience to variations in digital twin creation methods. Automated model creation was substantially faster than the manual approaches, suggesting that automatic digital twin analysis is the pathway toward future clinical scalability.
More Related Videos
07:12Semiautomated Longitudinal Microcomputed Tomography-based Quantitative Structural Analysis of a Nude Rat Osteoporosis-related Vertebral Fracture Model
Published on: September 28, 2017
08:41Calvarial Model of Bone Augmentation in Rabbit for Assessment of Bone Growth and Neovascularization in Bone Substitution Materials
Published on: August 13, 2019