Iontronic pressure sensor with a wide linearity range for "plug-and-play" fingertip pulse recording and statistical
Lingyu Zhao1, Minkun Cai1,2, Siqi Lu3
1Department of Materials Science and Engineering, Southern University of Science and Technology, Shenzhen 518055, China. zhaoly@sustech.edu.cn.
Abstract:
Cardiovascular diseases are a serious threat to humans. Arterial pulse monitoring using wearable electronics could help to assess the cardiac conditions of the wearer, which further reduces the possibility of a sudden lethal heart attack. However, pulse sensors are usually tightly bonded to the wrist during pulse monitoring. This scenario brings great discomfort to the wearer, but also causes unreliable pulse recording due to the susceptibility of motions and pressure sensing nonlinearity with high preload. To this end, a 3D-printed iontronic pressure sensor with high sensitivity (11.65 pF kPa-1) and ultrawide linearity range (150 kPa) was developed, which could monitor a fingertip pulse wave in a "plug-and-play" manner. The wide linearity range enabled the sensor to accurately record the fingertip pulse with variable applied preload, which dramatically improved the reliability of practical pulse sensing. The sensor was applied for monitoring the pulse of patients with cardiovascular diseases, and the correlation between disease type and characteristic pulse waveforms was analyzed. The superior pulse monitoring performance, as well as unprecedented operational convenience, highlights the great potential of the as-prepared pulse sensor in wearable health monitoring.
More Related Videos
Related Concept Videos
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Measurement of Blood Pressure
Special considerations while measuring pulse
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure: