Related Experiment Video
Updated: May 6, 2026

The Measurement of Unsteady Surface Pressure Using a Remote Microphone Probe
Published on: December 3, 2016
Noise reduction characteristics of broadband seismometer enclosures
Wenchao Bao1, Quan An1, Hao Zhai1
1Inner Mongolia Autonomous Region Earthquake Administration, Hohhot, Inner Mongolia Autonomous Region, China.
Abstract:
Broadband seismometers, distinguished by their large dynamic range and wide bandwidth, have seen increasingly widespread application in earthquake early warning systems and seismological research in recent years. A quantitative investigation into the discrepancies in background noise Power Spectral Density (PSD) recorded by co-located broadband seismometers, operating with and without protective enclosures, is of substantial importance for enhancing the data quality and improving the utilization efficiency of these instruments. This paper utilizes co-located observational data from seismographic instruments (equipped with enclosures) and early warning sensors (without enclosures), installed at earthquake early warning reference stations in the Inner Mongolia region, to quantitatively investigate the noise reduction characteristics of seismometer enclosures across various frequency points, under different spatio-temporal conditions, for different components, and in diverse observational settings. The results demonstrate that subsequent to the installation of seismometer enclosures: Within the low-frequency band of 0.02-0.05 Hz, the enclosures effectively mitigate temperature fluctuations and airflow disturbances, thereby suppressing background noise. The efficacy of this suppression exhibits dependencies on both component orientation and frequency; specifically, the suppression of horizontal noise components exceeds that of the vertical component, with this noise-reducing effect becoming increasingly prominent at longer periods. The mean difference for the East-West component is 3.5 dB (median: 1 dB), while the mean difference for the vertical component is 2.2 dB. This characteristic is consistently corroborated by amplitude-squared coherence analyses performed on teleseismic event data (with the difference between the two components being approximately 0.2). Furthermore, surface-based installations benefit more significantly from such noise reduction than those situated in vaults or caves, a difference potentially attributable to the inherently greater thermal stability of subterranean environments. In the primary microseism band (0.05-0.1 Hz), the enclosures provide a discernible noise reduction effect, suggesting that the sources of primary microseisms are not solely oceanic in origin but are also modulated to some extent by the local environment proximal to the seismometer. Conversely, in the secondary microseism band (0.1-0.5 Hz) and the high-frequency band (0.5-40 Hz), the enclosures offer essentially no discernible noise reduction.
Related Concept Videos
Types of Damping
Concept of Resonance and its Characteristics
Modes of Standing Waves - I
Shock Waves
When the source's speed approaches the speed of sound, constructive interference between successive wavefronts emitted by the source occurs immediately behind it. Initially, scientists believed that this constructive interference would result in such high...
Echo
Imagine the sound is reflected back to the ears. Assuming that the source is very close to the human, the difference between hearing the two sounds—the emitted sound and the reflected sound—may be more than the minimum time for perceiving distinct sounds. If this is the case,...
Dynamic Modulus of Elasticity of Concrete
The sonic test is a common method to determine the dynamic modulus. In this test, a concrete beam, sized either 6 x 6 x 30 inches or 4 x 4 x 20 inches, is clamped at its center. Vibrations are initiated at one end of the beam by an electromagnetic exciter unit powered by a...

