Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview01:19

Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview

1.7K
In inductively coupled plasma–mass spectrometry (ICP–MS), an inductively coupled plasma (ICP) torch is used as an atomizer and ionizer. Solid samples are dissolved and volatilized before being introduced into the high-temperature argon plasma, while solution samples are nebulized and passed through the high-temperature argon plasma. Plasma dissociates the analytes and ionizes their component atoms to form a mixture of positive ions and molecular species. The positive ions are then...
1.7K
Electrospray Ionization (ESI) Mass Spectrometry01:12

Electrospray Ionization (ESI) Mass Spectrometry

2.0K
Higher molecular weight biomolecules are nonvolatile compounds that may decompose before ionizing or vaporizing during mass analysis with conventional electron impact ionization methods. Accordingly, electrospray ionization (ESI) is the favored method for vaporizing and ionizing biomolecules as it circumvents rapid fragmentation and enables the recording of mass signals for the entire biomolecule.
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
2.0K
High-Resolution Mass Spectrometry (HRMS)01:15

High-Resolution Mass Spectrometry (HRMS)

2.3K
The resolution of a mass spectrometer depends on the efficiency of separating ions with different ion masses. The mass of an atom is approximated to the sum of the masses of protons and neutrons inside, considering the masses of protons and neutrons as equal. However, the masses of the proton (1.6726 × 10−24 g) and neutron (1.6749 × 10−24 g) are not truly equal. There is a minor error in the expression of atomic masses relative to the simplest atom of hydrogen. For...
2.3K
Chemical Ionization (CI) Mass Spectrometry01:21

Chemical Ionization (CI) Mass Spectrometry

1.4K
The molecular ion peak of a molecule in the mass spectrum provides vital information for molecular identification. However, conventional electron impact ionization can lead to the rapid dissociation of some molecular ions before they reach the detector. A milder ionization method is required to increase the lifetime of such ionized analyte molecules. Chemical ionization (CI) is a gas-phase protonation reaction useful for mass-analyzing analyte molecules that are easily protonated to yield the...
1.4K
Mass Analyzers: Overview01:13

Mass Analyzers: Overview

1.5K
The mass analyzer is a crucial component of the mass spectrometer. In the ionization chamber, the vaporized sample is bombarded with a high-energy electron beam to generate a radical cation and further fragment into neutral molecules, radicals, and cations. A series of negatively charged accelerator plates accelerate the cations into the mass analyzer. The mass analyzer separates ions according to their mass-to-charge (m/z) ratios and then directs them to the detector. The common types of mass...
1.5K
Mass Analyzers: Common Types01:19

Mass Analyzers: Common Types

1.3K
The quadrupole mass analyzer consists of four cylindrical metal rods arranged in a diamond carrying a DC voltage and a radio-frequency AC voltage. The motion of ions through the quadrupole depends on the field strength, causing only ions of a certain m/z to resonate successfully and strike the detector at a given field strength. Though the transmission rate for these analyzers is high, the exact elemental composition of the sample is not determined because of low resolution; however, they are...
1.3K

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

High-Resolution Ion Mobility-Based Isotopic Shifts of Dimethylated Peptide Isomers.

Analytical chemistry·2026
Same author

Improving Peak Capacity in Glycan Ion Mobility Separations through Traveling Wave-Based Ion Heating.

Journal of the American Society for Mass Spectrometry·2025
Same author

Integrating High-Resolution Cyclic Ion Mobility Separations with Tandem Mass Spectrometry and Collision Cross Section Measurements for Human Milk Oligosaccharide Sequencing.

ACS measurement science au·2025
Same author

Developing Reduced Mass-Only Ion Mobility Separations to Unravel Mass Distribution-Based Isotopic Shifts.

Journal of the American Society for Mass Spectrometry·2025
Same author

Determining β-Monosaccharide Head Group Composition with High-Resolution Cyclic Ion Mobility Separations Coupled to Tandem Mass Spectrometry as a First Step for Unknown Cerebroside Analysis.

International journal of mass spectrometry·2025
Same author

Two-dimensional isotopic shifts for steroid isomer delineation with high-resolution cyclic ion mobility separations.

Analytical and bioanalytical chemistry·2025

Related Experiment Video

Updated: Jan 7, 2026

Using a Cyclic Ion Mobility Spectrometer for Tandem Ion Mobility Experiments
08:40

Using a Cyclic Ion Mobility Spectrometer for Tandem Ion Mobility Experiments

Published on: January 20, 2022

4.8K

Spatial Ion Compression without Loss of Resolution on a Cyclic Ion Mobility Spectrometry-Mass Spectrometry Platform.

Paige E Robinson1, Noah D Roberts1, Gabe Nagy1

  • 1Department of Chemistry, University of Utah, 315 South 1400 East, Room 2020, Salt Lake City, Utah 84112, United States.

Analytical Chemistry
|December 24, 2025
PubMed
Summary

A new spatial ion compression strategy for traveling wave ion mobility spectrometry-mass spectrometry (TWIMS-MS) improves peak width and sensitivity. This method enhances biomolecule resolution without hardware changes, offering better feature detection and compound separation.

More Related Videos

Detection of Regulated Ergot Alkaloids in Food Matrices by Liquid Chromatography-Trapped Ion Mobility Spectrometry-Time-of-Flight Mass Spectrometry
08:56

Detection of Regulated Ergot Alkaloids in Food Matrices by Liquid Chromatography-Trapped Ion Mobility Spectrometry-Time-of-Flight Mass Spectrometry

Published on: November 22, 2024

1.1K
Analyzing Large Protein Complexes by Structural Mass Spectrometry
15:35

Analyzing Large Protein Complexes by Structural Mass Spectrometry

Published on: June 19, 2010

24.7K

Related Experiment Videos

Last Updated: Jan 7, 2026

Using a Cyclic Ion Mobility Spectrometer for Tandem Ion Mobility Experiments
08:40

Using a Cyclic Ion Mobility Spectrometer for Tandem Ion Mobility Experiments

Published on: January 20, 2022

4.8K
Detection of Regulated Ergot Alkaloids in Food Matrices by Liquid Chromatography-Trapped Ion Mobility Spectrometry-Time-of-Flight Mass Spectrometry
08:56

Detection of Regulated Ergot Alkaloids in Food Matrices by Liquid Chromatography-Trapped Ion Mobility Spectrometry-Time-of-Flight Mass Spectrometry

Published on: November 22, 2024

1.1K
Analyzing Large Protein Complexes by Structural Mass Spectrometry
15:35

Analyzing Large Protein Complexes by Structural Mass Spectrometry

Published on: June 19, 2010

24.7K

Area of Science:

  • Analytical Chemistry
  • Biophysical Chemistry
  • Spectrometry

Background:

  • Traveling wave ion mobility spectrometry-mass spectrometry (TWIMS-MS) is crucial for analyzing biomolecules.
  • Peak broadening due to diffusion limits sensitivity and resolution in TWIMS-MS.
  • Existing peak compression strategies like CRIMP and temporal compression have resolution limitations.

Purpose of the Study:

  • To introduce a novel reinjection-based spatial ion compression strategy for TWIMS-MS.
  • To enhance peak compression without hardware or software modifications.
  • To improve sensitivity and resolution in TWIMS-MS analyses.

Main Methods:

  • Implemented a spatial ion compression strategy on a cyclic TWIMS-MS platform.
  • Involved slicing a mobility peak, storing it, and reinjecting it for compression.
  • Optimized timing for a gentle transition and remerging of ions.

Main Results:

  • Achieved significant reduction in peak widths.
  • Demonstrated improved sensitivity and signal-to-noise ratio for low-abundance species.
  • Enabled near baseline resolution of previously partially resolved compounds.

Conclusions:

  • The reinjection-based spatial ion compression strategy effectively reduces peak broadening.
  • This method enhances feature finding and resolution in TWIMS-MS.
  • The strategy is adaptable to various TWIMS-MS platforms with ion storage capabilities.