Fracture Load of Polyaryletherketone for 4-Unit Posterior Fixed Dental Prostheses: An In Vitro Study
Dalea M Bukhary1, Hasan Y Asiri1, Ruwaida Z Alshali1
1Oral and Maxillofacial Prosthodontics Department, Faculty of Dentistry, King Abdulaziz University, P.O. Box 80209, Jeddah 21589, Saudi Arabia.
Journal of Functional Biomaterials
|December 24, 2025
Summary
This study compared four-unit fixed dental prostheses (FDPs) made from PEEK, PEKK, and two types of zirconia. 3Y zirconia had the highest fracture load, while PEEK and 4Y zirconia showed comparable loads but different failure modes.
Area of Science:
- Dental Materials Science
- Biomaterials Engineering
- Mechanical Engineering
Background:
- Evaluating mechanical properties of CAD-CAM materials for fixed dental prostheses (FDPs) is vital for posterior load-bearing applications.
- Understanding fracture load and patterns informs material selection for long-term prosthesis success.
Purpose of the Study:
- To assess and compare the fracture load, modulus of elasticity, and fracture patterns of four-unit posterior FDPs fabricated from PEEK, PEKK, 3Y zirconia, and 4Y zirconia.
- To determine the suitability of these CAD-CAM materials for high-stress dental restorations.
Main Methods:
- Sixty-eight four-unit FDP frameworks were fabricated from PEEK, PEKK, 3Y zirconia, and 4Y zirconia.
- Three-point bending tests were conducted to evaluate fracture load and modulus of elasticity.
- Fracture patterns were analyzed visually and via scanning electron microscopy (SEM).
Main Results:
- 3Y zirconia exhibited the highest fracture load (2275 N), followed by 4Y zirconia (1034 N), PEEK (883 N), and PEKK (402 N).
- PEEK demonstrated ductile fracture, while PEKK and both zirconia groups showed brittle fracture patterns.
- PEEK and 4Y zirconia had similar fracture loads but distinct failure behaviors.
Conclusions:
- Material selection for posterior FDPs requires consideration of both fracture load and failure mode.
- 3Y zirconia offers superior fracture resistance but lacks flexibility; PEKK shows the lowest mechanical performance.
- PEEK and 4Y zirconia present viable options with different mechanical profiles for posterior restorations.
Related Concept Videos
Bone Remodeling
34.4K
Bone remodeling is a continuous and balanced process of bone resorption by osteoclasts and bone formation by osteoblasts. In adults, it helps maintain bone mass and calcium homeostasis. While mechanical stress can stimulate turnover as part of the normal maintenance and reparative process, several hormones also regulate bone remodeling.
34.4K
Fractures: Bone Repair
5.8K
Treatment for a fracture is based on the type of break, the bone affected, and the patient's age.
Minor fractures with no bone displacement are treated by immobilizing the fractured bone using a cast or splint. However, in the case of fractures with displaced bones, the broken bones are repositioned before immobilization to ensure successful healing without deformation and loss of function. The realignment of fractured bone ends is performed through a process called reduction. If the...
Minor fractures with no bone displacement are treated by immobilizing the fractured bone using a cast or splint. However, in the case of fractures with displaced bones, the broken bones are repositioned before immobilization to ensure successful healing without deformation and loss of function. The realignment of fractured bone ends is performed through a process called reduction. If the...
5.8K