Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition
Published on: March 11, 2021
Clinical factors affecting the therapeutic dose window in cervical cancer brachytherapy: A systematic review and
Robin Straathof1, Lotte I Pool1, Sharline M van Vliet-Pérez2
1Department of BioMechanical Engineering, Delft University of Technology, Delft, The Netherlands.
Background And Purpose:
Although dose planning aims in cervical cancer brachytherapy are well-defined, variability in clinical practices makes it difficult to draw generalizable conclusions on achievable dosimetry. This review and meta-regression aim to assess clinical practices in terms of their therapeutic dose window, that is, the balance between target and organs-at-risk (OAR) doses.
Materials And Methods:
A search of the literature was performed in Scopus, PubMed, and Web of Science databases. Peer-reviewed articles were included that described planning constraints and reported high-risk clinical target volume (CTVHR) D90% and OAR [Formula: see text] for intracavitary (IC) tandem and ring (T&R) / tandem and ovoid (T&O) / mold (M) applicators, possibly supplemented with interstitial (IS) needles (+N). To determine factors associated with target volume coverage (D90%) and OAR sparing ( [Formula: see text] ), multivariate meta-regressions were performed.
Results:
Out of 1590 articles, 34 met the full inclusion criteria. In most studies, the CTVHRD90% aimed at ≥84-86 Gy EQD2α/β = 10Gy, and constraints for the OARs were 80-90 Gy, 65-75 Gy and 70-75 Gy EQD2α/β = 3Gy for the bladder, rectum and sigmoid [Formula: see text] , respectively. Studies using IC/IS applicators were associated with a ∼4 Gy increase in CTVHRD90% compared to IC only, with no effect on OAR dose. T&R studies achieved improvements of 3.2 Gy and 2.8-3.4 Gy at typical planning aims in comparison with T&O applicators in target and OAR doses. In 100% (15/15) of patient groups treated with T&R + N both CTVHR and OAR objectives were met for the population average. For T&R, T&O, and T&O + N groups, this was the case in 89% (8/9), 43% (6/14), and 50% (4/8), respectively.
Conclusion:
Studies using interstitial needles with T&R applicators in MR-guided brachytherapy for cervical cancer seem to be associated with a favorable therapeutic target dose/OAR sparing ratio.
Related Concept Videos
Therapeutic Drug Monitoring: Affecting Factors
Dosage Regimen: Individualization
Dosage Regimens: Designs and Approaches
Cancer Therapies
However, cancer treatments can pose several challenges, as therapies used to kill cancer cells are generally also toxic to normal cells. Moreover, cancer cells mutate rapidly and can develop resistance to chemical agents or radiation therapy. Besides, all types of cancer cells may not respond to the same therapy. Some cancer cells respond to one...
Dose Size and Dosing Frequency: Determination Methods
Cancer Survival Analysis