Related Experiment Video
Updated: Jan 7, 2026

Author Spotlight: Advancing Hepatic Fibrosis Diagnosis Using Magnetic Resonance Elastography and AI
Published on: July 21, 2023
Is FIB-4 the right tool for screening for liver fibrosis?
Leen Jm Heyens1, Demi P A van Malde2, Gediz Dogay Us3
1Hasselt University, Faculty of Health and Life Sciences/LCRC, Diepenbeek, Belgium; Maastricht University, School of Nutrition and Translational Research in Metabolism, NUTRIM, Maastricht, the Netherlands; Ziekenhuis Oost-Limburg, Department of Gastro-enterology and Hepatology and Department Future Health, Genk, Belgium.
Introduction And Objectives:
The screening accuracy of non-invasive fibrosis tests like FIB-4 in metabolic dysfunction-associated steatotic liver disease (MASLD) remains unclear. Using standard cut-offs, this study evaluated FIB-4's agreement with vibration-controlled transient elastography (VCTE) and identified and validated new thresholds.
Patients And Methods:
A prospective cohort study (2019-2024) in Belgian and Dutch primary care used VCTE by FibroScan® (Echosens, France) as a proxy for the fibrosis stage. The FIB-4 index was derived from electronic patient data and study blood samples. Agreement between VCTE and FIB-4 was analysed using weighted Cohen's kappa. New fibrosis cut-offs (≥F2; ≥8 kPa) for ≤65 and >65 years were determined via Youden's Index and validated in a Turkish primary care cohort and a Belgian secondary care T2DM cohort.
Results:
Among 563 participants (median age 62 years, 47.1 % male, 14.2 % with T2DM, median BMI 28.2 kg/m²), FIB-4 showed poor agreement with VCTE (κ = 0.138, 95 % CI: 0.069-0.207). Suggested new cut-offs of 1.29 (≤65 years) and 1.72 (>65 years) were proposed. The 1.29 cut-off performed similarly to the existing 1.3 in validation cohorts. In the Türkiye and T2DM cohorts, the 1.72 cut-off improved sensitivity over 2.0 but had lower specificity.
Conclusions:
The FIB-4 index showed poor agreement with VCTE and low sensitivity, making it an unreliable standalone diagnostic tool for liver fibrosis in people with MASLD in both primary and secondary care. Alternative non-invasive tests or improved cut-off values are needed for accurate fibrosis detection in clinical practice.
More Related Videos
05:56Implementation of Non-invasive Point of Care Transient Elastography for Evaluation of Liver Disease in Pediatric Populations with Cystic Fibrosis
Published on: August 29, 2025
10:10Measurement of Liver Stiffness Using Atomic Force Microscopy Coupled with Polarization Microscopy
Published on: July 20, 2022
Related Concept Videos
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):
Effect of Hepatic Disease on Pharmacokinetics: Pathophysiologic Assessment and Liver Function Test
Effect of Hepatic Disease on Pharmacokinetics: Drug Dosing and Hepatic Blood Flow