Related Experiment Video
Updated: Jan 7, 2026

An In Vitro Skin Irritation Test SIT using the EpiDerm Reconstructed Human Epidermal RHE Model
Published on: July 13, 2009
Review of simplified testing method for performance evaluation to assist in the selection of chemical protective
Satoko Iwasawa1, Takamasa Aoki2, Morinao Fukuoka3
1Department of Preventive Medicine and Public Health, National Defense Medical College, Tokorozawa-shi, Japan.
Objective:
There is a demand for information on the proper selection, use, and maintenance of impermeable chemical protective gloves to prevent direct skin contact with hazardous substances. This review aims to summarize simplified testing methods for evaluating glove performance.
Methods:
The survey highlighted a lack of awareness regarding permeation resistance in glove selection. Various simplified testing methods were developed, such as real-time monitoring and gas chromatography, to evaluate the permeation resistance of chemical protective gloves, including the efficacy of multilayer films in reducing permeation.
Results:
The investigation revealed significant flaws in glove selection regarding permeation resistance to chemicals. Analysis showed that thin nitrile gloves offer inadequate protection against chloroform, while laminated film gloves demonstrated strong resistance to various chemicals. Real-time monitoring facilitated glove performance evaluation and confirmed that commonly used gloves may still allow harmful substances to permeate.
Conclusion:
The review underscores the urgent need for simplified permeation testing methods, enabling workers to make informed choices about glove materials based on their specific workplace hazards. Implementing these testing methodologies and adhering to updated safety regulations will better protect workers from chemical exposure, particularly in environments handling hazardous substances. Further research and development of glove materials with improved permeation resistance are recommended to enhance occupational safety.
More Related Videos
09:02A Method to Test the Efficacy of Handwashing for the Removal of Emerging Infectious Pathogens
Published on: June 7, 2017
10:13Eye Irritation Test EIT for Hazard Identification of Eye Irritating Chemicals using Reconstructed Human Cornea-like Epithelial RhCE Tissue Model
Published on: August 23, 2015
Related Concept Videos
In Vitro Drug Dissolution: Compendial Testing Models II
Personal Protective Equipment
PPE Use in Healthcare Settings I: Donning