Equivalence of analog and digital high-frequency electrocardiogram: validating Sydäntek for ischemia detection
Aishwarya Srinivasan1, K Vijayalakshmi2, Sathish Kumar3
1Department of Electronics and Communication Engineering, BMS College of Engineering, Bengaluru, India. aishu.s.255@gmail.com.
Abstract:
High-frequency electrocardiography (HF-ECG) enhances ischemia detection by capturing microvolt-level changes in the QRS complex; however, clinical adoption requires validating digital systems against Analog standards. We recorded HF-ECG signals simultaneously from 12 healthy subjects (84 beats total) using a five-stage Analog reference (100-500 Hz band-pass, gold connectors) and Sydäntek's 10× capacitive sensors; both outputs were digitized using a Texas Instruments ADS1298. Signals underwent 10× amplification with a low-noise op-amp, the Analog output was scaled to match, and data were processed in PulseTek™ and stored in PulseVault™. Root mean square (RMS), Amplitude, Kurtosis, and Frequency content were compared using Bland-Altman analysis (Analog as the reference); values reported reflect pre-amplified measurements in microvolts (µV). Mean differences between the Analog setup and Sydäntek fell within the 95% limits of agreement (LOA): RMS, 6.39 µV (- 49.74 to 62.52 µV); amplitude, 1.82 µV (- 57.09 to 60.73 µV); kurtosis, 1.93 (- 5.13 to 1.54); and frequency, 2.1 Hz (- 5.8 to 6.2 Hz), all within a 5% clinical tolerance when scaled 10× (~ 10-20 mV). Sydäntek matched analog fidelity, with frequency peaks near ~ 150 Hz, indicating digital HF-ECG performance equivalent to that of the Analog system on key metrics. Its wearable design and cloud integration provide a portable, reliable alternative for ischemia detection with broader clinical applicability.
More Related Videos
Related Concept Videos
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and...
Dysrhythmias V: Evaluating Dysrhythmias
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...
Acute Coronary Syndrome III: Diagnostic Studies
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion,...
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...