Related Experiment Video
Updated: Jan 7, 2026

Evaluating Targeting Accuracy in the Focal Plane for an Ultrasound-guided High-intensity Focused Ultrasound Phased-array System
Published on: March 6, 2019
DCL-A: An Unsupervised Ultrasound Beamforming Framework with Adaptive Deep Coherence Loss for Single Plane Wave
Taejin Kim1, Seongbin Hwang2, Minho Song3
1Department of Computer Science and Information Engineering, The Catholic University of Korea, Bucheon 14662, Republic of Korea.
Abstract:
Background/Objectives: Single plane wave imaging (SPWI) offers ultrafast acquisition rates suitable for real-time ultrasound imaging applications; however, its image quality is compromised by beamforming artifacts such as sidelobe and grating lobe interferences. Methods: In this paper, we introduce an unsupervised beamforming framework based on adaptive deep coherence loss (DCL-A), which employs linear (αlinear) or nonlinear weighting (αnonlinear) within the coherence loss function to enhance the artifact suppression and improve overall image quality. During training, the adaptive weight (α) is determined by the angular distance between the input and target PW frames, assigning lower α values for smaller distances and higher α values for larger distances. Therefore, this adaptability enables the method to surpass conventional DCL (no weighting) by emphasizing the different spatial correlation characteristics of mainlobe and sidelobe signals. To assess the performance of the proposed method, we trained and validated the network using publicly available datasets, including simulation, phantom and in vivo images. Results: In the simulation and phantom studies, the DCL-A with αnonlinear outperformed the comparison methods (i.e., conventional DCL and DCL-A with αlinear) in terms of peak range sidelobe level (PRSLL), achieving 7 dB and 14 dB greater sidelobe suppression, respectively, while maintaining a comparable full width at half maximum (FWHM). In the in vivo study, it achieved the highest contrast resolution among the comparison methods, yielding 2% and 3% improvements in generalized contrast-to-noise ratio (gCNR), respectively. Conclusions: These results demonstrate that the proposed deep learning-based beamforming framework can significantly enhance SPWI image quality without compromising frame rate, indicating promising potential for high-speed, high-resolution clinical applications such as cardiac assessment and real-time interventional guidance.
Related Concept Videos
Imaging Studies II: Ultrasonography
Ultrasonography
During an ultrasonography procedure, a handheld device called...
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):
Ultrasound I: Abdominal Ultrasonography
Abdominal ultrasonography, commonly known as abdominal ultrasound, is a vital, non-invasive medical imaging technique widely used in healthcare.
Procedure:
This diagnostic tool allows the clinician to visually inspect internal structures within the abdomen, including vital organs such as the liver, gallbladder, pancreas, kidneys, and spleen.
The abdominal ultrasound process begins with applying a special gel to the patient's skin over the abdomen. This gel enhances the...
Imaging Biological Samples with Optical Microscopy
In optical microscopy, the specimen to be viewed is placed on a glass slide and clipped on the stage...
X-ray Imaging

