Molecular Imaging of Coronary Plaque Vulnerability Using 18F-Fluorocholine PET-MRI in Patients with Coronary Artery
Jochem A J van der Pol1,2, Braim Rahel3, Yvonne J M van Cauteren4
1Department of Radiology & Nuclear Medicine, Maastricht University Medical Center, 6229 HX Maastricht, The Netherlands.
Abstract:
Background/Objectives: 18F-fluorocholine is a positron emission tomography (PET) tracer earlier found to be a marker of macrophage content in carotid plaques. We aimed to assess the feasibility of 18F-choline PET-MRI to non-invasively localize vulnerable coronary plaques, using optical coherence tomography (OCT) as a reference standard. Methods: Patients with recent myocardial infarction who were scheduled for a secondary angiography of a non-culprit vessel underwent 18F-fluorocholine coronary PET-MRI. Subsequently, OCT was performed during the secondary angiography. Maximum target-to-background (TBRmax) values of 18F-fluorocholine uptake were determined in two vessel sections that contained either vulnerable or stable plaques as defined by OCT. The OCT-based definition of a vulnerable plaque was a fibrous cap thickness < 70 µm. To enhance the detectability of coronary plaques using PET, three different motion-correction strategies were used: multigate respiratory gating motion correction (MRG-MOCO), extended MR-based motion correction (eMR-MOCO), and extended MR-based motion correction with ECG gating (eMR-MOCO-ECG). Results: Fifteen patients were included in this study. One patient needed to be excluded due to extravasation of the tracer. In another patient, no region with only a stable plaque could be identified. TBRmax values were as follows for three different reconstructions in vulnerable versus stable plaques: MRG-MOCO: mean TBRmax 1.45 vs. 1.35, p = 0.52 (n = 13); eMR-MOCO: mean TBRmax 1.47 vs. 1.27, p = 0.26 (n = 11); eMR-MOCO-ECG: mean TBRmax 1.49 vs. 1.26, p = 0.21 (n = 11). Conclusions: 18F-fluorocholine uptake in vulnerable atherosclerotic plaques in coronary arteries was not significantly different from uptake in stable plaques, even though advanced motion-correction methods were applied. That may be caused by multiple factors, such as small coronary plaque size, tracer biology, or remaining cardiac motion.
Related Concept Videos
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Imaging Studies for Cardiovascular System V: CT
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Imaging Studies for Cardiovascular System IV: CMRI
![Quantification of Atherosclerotic Plaque Activity and Vascular Inflammation using [18-F] Fluorodeoxyglucose Positron Emission Tomography/Computed Tomography FDG-PET/CT](/_next/image?url=https%3A%2F%2Fcloudfront.jove.com%2FCDNSource%2Fteasers%2F3777.jpg&w=3840&q=50)