Related Experiment Video
Updated: Jan 7, 2026

07:47
Reverse Transcription Loop-Mediated Isothermal Amplification RT-LAMP Assay for the Specific and Rapid Detection of Tilapia Lake Virus
Published on: May 18, 2020
13.1K
Innovative Colorimetric Neutral Red-Based Loop-Mediated Isothermal Amplification (NR-LAMP) Assay: Transforming Rapid
Witsanu Rapichai1,2,3, Piyamat Khamsingnok2, Anyalak Wachirachaikarn4
1Center for Advanced Studies for Agriculture and Food, Kasetsart University Institute for Advanced Studies, Kasetsart University, Bangkok 10900, Thailand.
International Journal of Molecular Sciences
|December 30, 2025
Summary
A new colorimetric loop-mediated isothermal amplification (NR-LAMP) assay offers a highly sensitive and specific method for detecting feline leukemia virus (FeLV). This cost-effective molecular tool provides a reliable alternative for FeLV diagnostics.
Area of Science:
- Veterinary Virology
- Molecular Diagnostics
- Retroviral Research
Background:
- Feline leukemia virus (FeLV) is a global retrovirus causing severe feline diseases like leukemia and lymphoma.
- Current antigen tests for FeLV can produce false negatives, necessitating more accurate diagnostic methods.
- FeLV infection leads to immunosuppression, increasing susceptibility to other infections in cats.
Purpose of the Study:
- To develop and validate a novel, highly sensitive, and specific diagnostic assay for FeLV detection.
- To establish a cost-effective and efficient molecular method as an alternative to existing FeLV tests.
- To design a colorimetric assay for easy visual interpretation of FeLV diagnostic results.
Main Methods:
- Development of a colorimetric loop-mediated isothermal amplification (LAMP) assay using neutral red (NR-LAMP).
- Custom design of a novel LAMP primer set targeting the FeLV pol gene for enhanced specificity.
- Optimization of isothermal amplification conditions (61 °C for 40 min) and validation against polymerase chain reaction (PCR).
Main Results:
- The NR-LAMP assay achieved a detection limit of 10^0 copies/µL, demonstrating high sensitivity.
- Specificity was confirmed with no cross-amplification with other feline viruses.
- Clinical testing on 98 samples showed perfect agreement with PCR, yielding 97.3% sensitivity and 100% specificity.
Conclusions:
- The developed NR-LAMP assay is a robust, sensitive, and specific molecular diagnostic tool for FeLV.
- This assay offers superior performance and cost-effectiveness compared to existing methods.
- NR-LAMP presents a convenient and reliable alternative for FeLV inspection in clinical and commercial settings.