Related Experiment Video
Updated: Jan 7, 2026

Veno-Venous Extracorporeal Membrane Oxygenation in a Mouse
Published on: October 24, 2018
Prevalence and microbiological profile of septic complications following ECMO decannulation: a prospective
Simone Kattner1, Ksenia Pawlytta1, Andrea Engler1
1Department of Anesthesiology and Intensive Care Medicine, University Hospital Essen, University Duisburg-Essen, Essen, Germany.
Abstract:
Extracorporeal membrane oxygenation (ECMO) is widely used to manage acute respiratory distress syndrome (ARDS); however, biofilm formation on cannulas may contribute to infections. This study investigated the prevalence, timing, and microbial profiles of infectious complications following ECMO decannulation. This prospective, single-center cohort study was conducted in the mixed medical-surgical intensive care unit (ICU) at the University Hospital Essen (01/2022-01/2023). Adults who received ECMO for > 48 h were included. Microbiological sampling (blood cultures and wound swabs) was performed before and after decannulation. Cannulas were assessed for biofilms, and plasma samples were analyzed using next-generation sequencing (NGS) of microbial cell-free DNA (cfDNA). Sepsis was defined according to the most recent Sepsis-3 criteria. The study included 18 patients (56% men); 17 received VV-ECMO and one received VA-ECMO. Post-decannulation sepsis occurred in 10 of 18 patients (56%; 95% CI: 31-79%), and overall infectious complications were observed in 72% of patients. A strong negative correlation was evident between pre-ECMO ventilation duration and biofilm-forming bacteria in the blood during ECMO (r = - 0.7, p = 0.002). Blood cultures obtained within 10 min of decannulation were positive in 6 of 18 (33%) patients. NGS identified pathogens in 9 of 12 patients (75%), with 5 (42%) revealing additional organisms not detected by conventional methods. Viral pathogens were detected in 3 of 12 (25%) patients using NGS. Patients with sepsis demonstrated higher antibiotic consumption (p = 0.012) and more frequently met SOFA-based sepsis criteria (p = 0.007), whereas other parameters were comparable. Sepsis and infection frequently occur after ECMO decannulation and may be associated with biofilm-related pathogens. NGS has improved pathogen detection beyond standard diagnostics, although the findings require clinical correlation. These prospective findings support the need for further investigation of advanced integrated microbiological surveillance post-ECMO in larger multicenter studies.Trial registration: DRKS, DRKS00024842. Registered 12 Apr 2021, https://drks.de/search/de/trial/DRKS00024842 .
More Related Videos
03:40Point-of-Care Ultrasound for Peripheral Veno-Arterial Extracorporeal Membrane Oxygenation Without Left Ventricular Venting
Published on: January 17, 2025
09:54Lung Rapid Recovery Procurement Combined with Abdominal Normothermic Regional Perfusion in Controlled Donation after Circulatory Death
Published on: August 15, 2022
Related Concept Videos
Tracheostomy Decannulation
Description of the Procedure
Decannulation refers to the permanent removal of the tracheostomy tube, signaling the resolution of the condition that initially necessitated the tracheostomy. The process requires a well-coordinated interplay between...
Pulmonary Embolism II: Diagnostic Studies and Interprofessional Care
Endoscopic Studies II: Thoracocentesis
Description
Excess pleural fluid or air may accumulate in some respiratory disorders in the thoracic cavity. To treat pleural effusion, a physician conducts thoracentesis by carefully piercing the chest wall and entering...
Pneumonia III: Complications and Assessment
Peritoneal Dialysis II: Peritoneal Dialysis Systems and Complications
Factors Affecting the Risk of Infection
The integrity and count of the white blood cells help the body resist pathogens and fight infection. When impaired, it reduces the body's resistance to pathogens. The acidic pH levels of the gastrointestinal, genitourinary tracts, and skin...