Related Experiment Video
Updated: Jan 7, 2026

Investigating the Potential of Singly Curved Thin Piezoelectric Transducers for Energy Harvesting and Structural Health Monitoring
Published on: November 14, 2025
Piezoelectric Energy Harvester with Zigzag Root Section for Self-Powered Transformer Monitoring
Jiawen Xu1,2, Zixuan Xia1, Yebao Xia3
1Jiangsu Key Laboratory of Robot Sensor and Control Laboratory, School of Instrument Science and Engineering, Southeast University, Nanjing 210096, China.
Abstract:
A slender piezoelectric cantilever for energy harvesting features high efficiency but a low operational frequency, which cannot meet the requirements for self-powered transformer monitoring. In this research, a piezoelectric vibration energy harvester with a zigzag root section was proposed. The harvester has a vertically arranged zigzag root section, enabling the capability of integrating multiple piezoelectric transducers as well as increasing the resonant frequency and reducing strain. A linear electromechanical coupling model was formulated. The theoretical and experiential base-movement analysis demonstrates that the zigzag root section of the piezoelectric cantilever beam can effectively reduce the equivalent mass of the system and thereby increase the resonant frequency of the slender beam to 100 Hz, the vibration frequency of a transformer. It was also experimentally shown that the harvester can output 13.54 mW of power. An STM32 microcontroller (MCU) based sensor node with a wireless data transmission module was then designed for evaluations. The piezoelectric harvester with a zigzag root section can successfully support a wireless sensor for transformer monitoring.
More Related Videos
09:51A Polymer-based Piezoelectric Vibration Energy Harvester with a 3D Meshed-Core Structure
Published on: February 20, 2019
10:39Preparation of ZnO Nanorod/Graphene/ZnO Nanorod Epitaxial Double Heterostructure for Piezoelectrical Nanogenerator by Using Preheating Hydrothermal
Published on: January 15, 2016
Related Concept Videos
Energy Losses in Transformers
There are four main reasons for energy losses in transformers.
The first cause can be the high resistance of the...
Three-Winding Transformers
In the per-unit equivalent circuit of a grounded Y-Y three-phase...
Half wave rectifier
Full wave rectifier
Induced Electric Fields: Applications
Equivalent Circuits for Practical Transformers