Related Experiment Video
Updated: Jan 7, 2026

Shrinkage of Dental Composite in Simulated Cavity Measured with Digital Image Correlation
Published on: July 21, 2014
Viscosity-Dependent Shrinkage Behavior of Flowable Resin Composites
Nadja Jeconias1, Peter Fischer2, Tobias T Tauböck1
1Department of Conservative and Preventive Dentistry, Center for Dental Medicine, University of Zurich, Plattenstrasse 11, 8032 Zurich, Switzerland.
Abstract:
Flowable resin composites are extensively used in restorative dentistry, where linear polymerization shrinkage and the resulting shrinkage stress are critical for clinical success. This study investigated the relationship between viscosity, linear polymerization shrinkage, and shrinkage stress in flowable resin composite materials. Two low-flow resin composites (Beautifil Flow Plus F00, Estelite Universal Flow SuperLow), two medium-flow resin composites (Tetric EvoFlow, Estelite Universal Flow Medium), and two high-flow resin composites (Beautifil Flow F10, Estelite Universal Flow High) were examined. Viscosity (n = 3) of the unset materials was determined using a cone-plate rheometer. The composites were photoactivated for 20 s at 1226 mW/cm2, and linear polymerization shrinkage (n = 8) and shrinkage stress (n = 8) of 1.5 mm-thick specimens were recorded in real time for 5 min using a custom-made linometer and stress analyzer, respectively. Data were analyzed with Kruskal-Wallis rank tests followed by Conover post hoc tests, and Spearman correlation analyses were conducted to assess relationships between parameters (α = 0.05). A significant negative correlation was observed between viscosity and shrinkage stress (r = -0.943, p = 0.017). Beautifil Flow F10 exhibited the significantly lowest viscosity (14.60 ± 0.17 Pa·s) and the highest shrinkage stress (0.83 ± 0.14 MPa) among the materials, whereas low-flow composite Estelite Universal Flow SuperLow showed the lowest shrinkage stress (0.65 ± 0.10 MPa). Linear shrinkage ranged from 1.89 ± 0.13% to 3.18 ± 0.21%, but was not correlated with viscosity or stress (p > 0.05). In conclusion, viscosity critically influences polymerization-induced shrinkage stress development in flowable resin composites. Higher-viscosity flowable composites might be beneficial regarding stress build-up during polymerization compared with high-flow composites.
More Related Videos
09:41Magnet Assisted Composite Manufacturing: A Flexible New Technique for Achieving High Consolidation Pressure in Vacuum Bag/Lay-Up Processes
Published on: May 17, 2018
05:30Roughness Impact of Piezoelectric Dental Scaler on Two Distinct Flowable Composite Filling Materials
Published on: January 10, 2025
Related Concept Videos
Shrinkage in Concrete
When concrete is still in its plastic state, it can undergo a decrease in volume by about 1% of its absolute volume. This decrease is known as plastic shrinkage. It arises either...
Drying Shrinkage
A portion of this drying shrinkage can be reversed; if the concrete is...
Plastic Behavior
Carbonation Shrinkage
The concrete's permeability is slightly reduced as calcium carbonate produced during the reaction fills its pores. Furthermore, its strength is slightly enhanced as the water released during the reaction...
Viscosity of Fluid
Viscosity
The SI unit of viscosity is...