Reliability of pressure-volume loop parameters derived from transthoracic echocardiography in patients undergoing
Dinara Galiyeva1, Zaukiya Khamitova1, Aizhan Zhankorazova1
1Department of Medicine, Nazarbayev University School of Medicine, Astana, Kazakhstan.
Background:
The pressure-volume (PV) relationship remains a key tool for assessing cardiac function. PV loop derived parameters, including end-systolic elastance (Ees), effective arterial elastance (Ea), ventriculo-arterial coupling (VAC), stroke work (SW), pressure-volume area (PVA), and work efficiency (WE), are valuable tools, but reproducibility data are scarce.
Objective:
To evaluate the inter- and intra-observer variability of PV loop parameters derived from transthoracic echocardiography images in patients undergoing hemodialysis.
Methods:
Twenty-five adult patients with end-stage renal disease undergoing maintenance hemodialysis were randomly selected. PV loops were reconstructed using Q-Strain software (version 1.3.0.79, Medis, Leiden, the Netherlands), and parameters including Ees, Ea, VAC, SW, PVA, and WE were calculated. Two experienced readers performed measurements for inter-observer analysis; one reader repeated measurements one week apart for intra-observer analysis. Reliability was assessed using intraclass correlation coefficients (ICC) and Bland-Altman plots.
Results:
Inter-observer agreement was excellent for SW 0.96 (0.91-0.98) and PVA 0.95 (0.87-0.98), good for Ees 0.90 (0.77-0.96) and Ea 0.79 (0.49-0.91), and moderate for VAC 0.68 (0.23-0.85) and WE 0.72 (0.28-0.79). Intra-observer agreement was excellent for Ees 0.96 (0.90-0.98), Ea 0.98 (0.94-0.99), SW 0.98 (0.96-0.99) and PVA 0.98 (0.96-0.99), and good for VAC 0.78 (0.51-0.91) and WE 0.85 (0.65-0.94). Bland-Altman analysis showed minimal bias for Ees, SW and PVA, whereas Ea, VAC and WE exhibited proportional bias.
Conclusions:
PV loop-derived parameters obtained via transthoracic echocardiography demonstrate good-to-excellent reproducibility, particularly for Ees, Ea, SW and PVA. VAC and WE show moderate variability, suggesting careful interpretation of these parameters in clinical and research settings.
More Related Videos
07:56Closed Chest Biventricular Pressure-Volume Loop Recordings with Admittance Catheters in a Porcine Model
Published on: May 18, 2021
08:21Functional Assessment of the Donor Heart During Ex Situ Perfusion: Insights from Pressure-Volume Loops and Surface Echocardiography
Published on: October 11, 2022
Related Concept Videos
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Assessment of blood pressure in brachial artery(two-step method)